Differential Healing Responses in Polymer- and Nonpolymer-Based Sirolimus-Eluting Stents
Autor: | Michael C. John, Albert Schömig, Frank D. Kolodgie, Herman K. Gold, Renu Virmani, Johanna Crimins, Scott Lajoie, Rainer Wessely, Michael Joner, Aloke V. Finn, Adnan Kastrati, Mayu Uchihashi |
---|---|
Rok vydání: | 2008 |
Předmět: |
medicine.medical_specialty
endothelium Endothelium Polymers polymer VEGF receptors Urology Prosthesis Design Iliac Artery Organ Culture Techniques Fibrinolytic Agents medicine Animals Inflammation Sirolimus Wound Healing Iliac artery biology business.industry Cardiovascular Agents Drug-Eluting Stents Histology equipment and supplies Surgery Stent placement medicine.anatomical_structure Metals stents Models Animal Microscopy Electron Scanning biology.protein Rabbit model Cytokines Intercellular Signaling Peptides and Proteins Rabbits Cardiology and Cardiovascular Medicine business Delayed healing Angioplasty Balloon medicine.drug |
Zdroj: | JACC: Cardiovascular Interventions. 1:535-544 |
ISSN: | 1936-8798 |
DOI: | 10.1016/j.jcin.2008.08.004 |
Popis: | Objectives We compared the healing and inflammatory responses of polymer-free bare-metal stents (BMS), polymer-free sirolimus-eluting stents (SES) and polymer-free sirolimus-eluting stents plus estradiol (SES+ED) to Cypher drug-eluting stents (CDES) in a rabbit model of overlapping stent placement. Background Inflammatory responses to polymers and delayed healing remain important safety issues associated with CDES. Whether nonpolymeric stents that elute sirolimus or sirolimus and estradiol provoke less inflammation and heal better is unknown. Methods Twenty-eight rabbits received 2 overlapping stents in each iliac artery: SES, SES+ED, BMS, or CDES, and vessels were harvested at 28 days for histology and scanning electron microscopy. Results Although similar at nonoverlapping segments, neointimal thickness within the overlap site of CDES was significantly less than in SES, SES+ED, and BMS (0.07 ± 0.04 mm vs. 0.16 ± 0.03 mm, 0.14 ± 0.03 mm, and 0.15 ± 0.03 mm, p l 0.0001). Endothelialization was greater in SES, SES+ED, and BMS compared with CDES in nonoverlapping sections (80.0 ± 5.0% vs. 95.3 ± 5.0%, 97.5 ± 2.5%, and 96.7 ± 3.8%; p = 0.0028) and overlapping sections (85.8 ± 2.9% vs. 90.8 ± 6.3%, 89.2 ± 6.3%, and 48.3 ± 2.9%; p l 0.0001). The number of luminal eosinophils was also less in overlapping sections of SES, SES+ED, and BMS versus CDES but was similar in nonoverlapping sections. Conclusions Polymer-free stents coated with SES or SES+ED result in less robust neointimal suppression but markedly improved arterial healing compared with CDES in the rabbit model. |
Databáze: | OpenAIRE |
Externí odkaz: |