Coerência da banda alfa do EEG em nonagenários saudáveis
Autor: | Mário Silva Jorge, Renato Anghinah, Joyce Haruyo Biancon Katata, Lívia Spíndola |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: |
Male
Aging medicine.medical_specialty envelhecimento Eeg coherence Electroencephalography Audiology Brain mapping 050105 experimental psychology lcsh:RC321-571 Interviews as Topic 03 medical and health sciences 0302 clinical medicine Humans Medicine Coherence (signal processing) 0501 psychology and cognitive sciences Spectral analysis saúde do idoso lcsh:Neurosciences. Biological psychiatry. Neuropsychiatry health of the elderly Aged 80 and over Neurologic Examination Psychiatric Status Rating Scales Brain Mapping Resting state fMRI medicine.diagnostic_test business.industry 05 social sciences eletroencefalografia aging Brain idoso de 80 anos ou mais Alpha Rhythm Alpha band Neurology Closed eyes Educational Status Female Neurology (clinical) business aged 80 and over 030217 neurology & neurosurgery electroencephalography |
Zdroj: | Arquivos de Neuro-Psiquiatria v.75 n.9 2017 Arquivos de neuro-psiquiatria Academia Brasileira de Neurologia instacron:ABNEURO Arquivos de Neuro-Psiquiatria, Volume: 75, Issue: 9, Pages: 609-613, Published: SEP 2017 Arquivos de Neuro-Psiquiatria, Vol 75, Iss 9, Pp 609-613 |
Popis: | Electroencephalographic (EEG) coherence is a parameter that enables evaluation of cerebral connectivity. It may be related to the functional state of the brain. In the elderly, it may reflect the neuronal loss caused by aging. Objective To describe characteristics of coherence in nonagenarians. Methods We evaluated interhemispheric coherence for the alpha band in 42 cognitively normal individuals aged 90 to 101 years. Coherence values in the occipital electrode (O1O2), in the resting state with closed eyes, were calculated by means of spectral analysis using digital EEG EMSA 32 channels, 12 bits and a frequency of 200 Hz. Results The mean coherence value for the alpha band at O1O2 was 0.65 (SD 0.13). No significant differences were found between men and women. Conclusions The findings from this study did not show any decrease in interhemispheric coherence for the alpha band in cognitively normal nonagenarians. This may be useful as a standard value for this age group. RESUMO A coerência é um parâmetro que permite avaliar a conectividade cerebral, podendo se relacionar com o estado funcional do cérebro. Especialmente nos idosos, pode refletir a perda neuronal decorrente do envelhecimento. Objetivo Descrever características da coerência em nonagenários. Métodos Avaliamos a coerência interhemisferica para a banda alfa em 42 indivíduos cognitivamente normais entre 90 e 101 anos. Foram calculados através da análise espectral o valor da coerência nos eletrodos O1O2, em estado de repouso e olhos fechados, com EEG digital 32 canais marca EMSA 12 bits e frequência de amostragem 200 hz. Resultados O valor médio da coerência para a banda alfa entre O1O2 foi de 0,65 (DP 0,13). Não encontramos diferenças significativas entre homens e mulheres. Conclusão Os achados desse estudo não evidenciam diminuição da coerência interhemisferica para a banda alfa nos eletrodos O1O2 em nonagenários saudáveis e cognitivamente normais, podendo indicar um valor padrão para essa faixa etária. |
Databáze: | OpenAIRE |