Coerência da banda alfa do EEG em nonagenários saudáveis

Autor: Mário Silva Jorge, Renato Anghinah, Joyce Haruyo Biancon Katata, Lívia Spíndola
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Male
Aging
medicine.medical_specialty
envelhecimento
Eeg coherence
Electroencephalography
Audiology
Brain mapping
050105 experimental psychology
lcsh:RC321-571
Interviews as Topic
03 medical and health sciences
0302 clinical medicine
Humans
Medicine
Coherence (signal processing)
0501 psychology and cognitive sciences
Spectral analysis
saúde do idoso
lcsh:Neurosciences. Biological psychiatry. Neuropsychiatry
health of the elderly
Aged
80 and over

Neurologic Examination
Psychiatric Status Rating Scales
Brain Mapping
Resting state fMRI
medicine.diagnostic_test
business.industry
05 social sciences
eletroencefalografia
aging
Brain
idoso de 80 anos ou mais
Alpha Rhythm
Alpha band
Neurology
Closed eyes
Educational Status
Female
Neurology (clinical)
business
aged
80 and over

030217 neurology & neurosurgery
electroencephalography
Zdroj: Arquivos de Neuro-Psiquiatria v.75 n.9 2017
Arquivos de neuro-psiquiatria
Academia Brasileira de Neurologia
instacron:ABNEURO
Arquivos de Neuro-Psiquiatria, Volume: 75, Issue: 9, Pages: 609-613, Published: SEP 2017
Arquivos de Neuro-Psiquiatria, Vol 75, Iss 9, Pp 609-613
Popis: Electroencephalographic (EEG) coherence is a parameter that enables evaluation of cerebral connectivity. It may be related to the functional state of the brain. In the elderly, it may reflect the neuronal loss caused by aging. Objective To describe characteristics of coherence in nonagenarians. Methods We evaluated interhemispheric coherence for the alpha band in 42 cognitively normal individuals aged 90 to 101 years. Coherence values in the occipital electrode (O1O2), in the resting state with closed eyes, were calculated by means of spectral analysis using digital EEG EMSA 32 channels, 12 bits and a frequency of 200 Hz. Results The mean coherence value for the alpha band at O1O2 was 0.65 (SD 0.13). No significant differences were found between men and women. Conclusions The findings from this study did not show any decrease in interhemispheric coherence for the alpha band in cognitively normal nonagenarians. This may be useful as a standard value for this age group. RESUMO A coerência é um parâmetro que permite avaliar a conectividade cerebral, podendo se relacionar com o estado funcional do cérebro. Especialmente nos idosos, pode refletir a perda neuronal decorrente do envelhecimento. Objetivo Descrever características da coerência em nonagenários. Métodos Avaliamos a coerência interhemisferica para a banda alfa em 42 indivíduos cognitivamente normais entre 90 e 101 anos. Foram calculados através da análise espectral o valor da coerência nos eletrodos O1O2, em estado de repouso e olhos fechados, com EEG digital 32 canais marca EMSA 12 bits e frequência de amostragem 200 hz. Resultados O valor médio da coerência para a banda alfa entre O1O2 foi de 0,65 (DP 0,13). Não encontramos diferenças significativas entre homens e mulheres. Conclusão Os achados desse estudo não evidenciam diminuição da coerência interhemisferica para a banda alfa nos eletrodos O1O2 em nonagenários saudáveis e cognitivamente normais, podendo indicar um valor padrão para essa faixa etária.
Databáze: OpenAIRE