Error patterns in the MR imaging evaluation of menisci of the knee

Autor: S F Quinn, W W Justice
Rok vydání: 1995
Předmět:
Zdroj: Radiology. 196:617-621
ISSN: 1527-1315
0033-8419
Popis: To categorize errors in interpretation of magnetic resonance (MR) images of the knee and explain the discrepancy between MR imaging and diagnostic arthroscopic findings.Five hundred sixty-one patients underwent arthroscopy and MR imaging of the knee. Prospective and retrospective readings were used to categorize tear type and location. Sixty-six patients had 68 discrepancies between MR imaging and arthroscopic findings.Prospective interpretation of MR images of the lateral meniscus had a sensitivity of 82%, specificity of 98%, and accuracy of 93%. For images of the medial meniscus, sensitivity was 96%; specificity, 91%; and accuracy, 95%. The number of diagnostic errors at retrospective analysis was 76% (n = 52) of the number at prospective analysis.MR imaging is accurate in evaluation for meniscal tears. Most errors in interpretation that occur at prospective evaluation also occur at retrospective evaluation. Some false-positive errors may be related to incomplete arthroscopic evaluation of the meniscus and confusion between what represents fraying and what represents a tear.