Percutaneous closure of a postoperative residual atrial septal defect with the Occlutech Figulla Occluder device
Autor: | Osman Karakaya, Bülent Demir, Hande Oktay Tureli, Gönül Kutlu |
---|---|
Rok vydání: | 2012 |
Předmět: |
Male
medicine.medical_specialty Percutaneous Septal Occluder Device medicine.medical_treatment Septum secundum Residual Heart Septal Defects Atrial Diagnosis Differential Postoperative Complications Internal medicine medicine.artery medicine Humans Fatigue Aged Ultrasonography Mitral valve repair Mitral Valve Prolapse Pericardial patch business.industry Dyspnea Male patient Pulmonary artery Cardiology Cardiology and Cardiovascular Medicine business |
Zdroj: | Turk Kardiyoloji Dernegi Arsivi-Archives of the Turkish Society of Cardiology. 40:55-58 |
ISSN: | 1308-4488 1016-5169 |
DOI: | 10.5543/tkda.2012.01731 |
Popis: | A 67-year-old male patient with an eight-month history of operation for mitral valve repair and secundum atrial septal defect (ASD) presented with complaints of fatigue and shortness of breath. Transthoracic echocardiography showed a residual ASD resulting from separation of a pericardial patch. Qp/Qs rate was 3.2. The diameter of the residual defect measured by transesophageal echocardiography was 18 mm. During right heart catheterization, pulmonary artery pressure was estimated to be 50 mmHg. Using the percutaneous method accompanied by transesophageal echocardiography guidance, the residual defect was successfully closed with a 21-mm Occlutech Figulla device. Postprocedural echocardiographic control showed no leaks. The patient was discharged with 300 mg/day aspirin treatment. |