Monitoring of Rabbit Cornea Response to Dehydration Stress by Optical Coherence Tomography
Autor: | Alexander I. Kholodnykh, Rinat O. Esenaliev, Massoud Motamedi, Kamran Hosseini, Irina Y. Petrova, Fred Hendrikse |
---|---|
Rok vydání: | 2004 |
Předmět: |
medicine.medical_specialty
Light genetic structures Hypertonic Solutions Diagnostic Techniques Ophthalmological Corneal hydration Cornea Stress (mechanics) Body Water Optical coherence tomography Stress Physiological medicine Animals Scattering Radiation Dehydration Desiccation Monitoring Physiologic medicine.diagnostic_test Chemistry Water-Electrolyte Balance medicine.disease eye diseases Surgery Intensity (physics) medicine.anatomical_structure Tonicity Rabbits sense organs Tomography Optical Coherence Biomedical engineering |
Zdroj: | Investigative Opthalmology & Visual Science. 45:2555 |
ISSN: | 1552-5783 |
DOI: | 10.1167/iovs.03-0792 |
Popis: | PURPOSE. To evaluate the application of optical coherence tomography (OCT) for continuous noninvasive monitoring and quantification of the dynamics of corneal response after exposure of the cornea to dehydrating stress. METHODS. The changes in central corneal thickness (CCT) and scattering properties of the cornea were monitored with OCT in rabbit cornea in vivo after topical application of a glycerinbased hypertonic agent (HA) or prolonged surface evaporation of the cornea. The observed changes in backscatter were correlated with the changes in corneal hydration. RESULTS. An inverse relationship was found between the logarithm of the intensity of backscatter within the cornea and the degree of corneal hydration at which the intensity of the backscatter changed up to 20 times between the peak of the de- and rehydration phases. An analytical relationship is derived between the magnitude of the backscatter from the stroma and the extent of corneal hydration. Furthermore, depending on the concentration of the drug, a peak overshoot in corneal thickness in the range of 40% to 90% was detected during the rehydration process after topical application of the HA. At a 100% concentration of HA, the average dehydration rate was 74 m/min, whereas the average rehydration rate was 12.4 m/min. The same parameters for surface evaporation were 2.7 and 1.5 m/min, respectively. CONCLUSIONS. OCT may offer a unique capability to quantitatively monitor the dynamics of corneal response and to assess corneal function based on noninvasive detection of the changes in the optical properties and morphology of the cornea after topical application of dehydrating agents. (Invest Ophthalmol Vis Sci. 2004;45:2555‐2562) DOI:10.1167/ iovs.03-0792 |
Databáze: | OpenAIRE |
Externí odkaz: |