Popis: |
A system for measurement of attack-release times in hearing aids with automatic-gain-control circuitry is described, with a view toward implementing that portion of the ANSI S3.22-1976 Standard in which parameters for these measurements are specified. Signal generation is accomplished by using a phased-array loudspeaker arrangement designed to produce transient-free pulsed acoustic sinusoids. Output waveforms are captured by a commercial transient recorder, and are displayed in either an oscilloscopic or graphic mode. A specific means of calculating attack and release times is recommended whereby variously shaped output waveforms are amenable to the basic protocol outlined in the ANSI Standard. |