COMPARACIÓN DE LA FUERZA ADHESIVA Y EL TIPO DE FALLA DE DOS SISTEMAS ADHESIVOS PARA ORTODONCIA

Autor: Jaime Rodrigo Rivera Barrero, John Jairo Monroy Parada, Gerardo Ardila Duarte, Antonio Luna Salguero, Ana Lucía Ciceri
Jazyk: Spanish; Castilian
Rok vydání: 2011
Předmět:
Zdroj: UstaSalud; Vol. 10, Núm. 1 (2011); 29-35
ISSN: 1692-5106
DOI: 10.15332/us.v10i1
Popis: Objective: To compare the bond strength and failure mode between total and self-etching systems used for brackets cementation.Methods: Twenty human first premolars were randomly divided into two groups: 10 for the total etching system (Transbond™ XT, 3M Unitek, St. Paul, Minnesota, USA) and 10 for the self-etching system (Transbond™ Plus Self Etching Primer + Transbond™ XT, 3M Unitek, St. Paul, Minnesota, USA). Standard brackets (Ortho Organizers, California, USA) were cemented, and after 24 hours submitted to 5000 thermal cycles. Subsequently, shear bond strength tests were performed applying force at the bracket/enamel interphase using an universal testing machine (Instron®) at 1.5 mm/min crosshead speed. Finally, enamel surfaces and bracket bases were observed using a stereomicroscope (Stemi 2000C, Carl Zeiss, Göttingen, Germany).Results: The results, in terms of bond strength, showed a statistical significant difference (p
Databáze: OpenAIRE