Measurements of ramp-rate limitation of cable-in-conduit conductors
Autor: | T.A. Painter, M. M. Steeves, M.A. Ferri, Joseph Minervini, Makoto Takayasu, C.Y. Gung |
---|---|
Rok vydání: | 1993 |
Předmět: |
Condensed Matter::Quantum Gases
Physics Limiting current Mechanics Superconducting magnet Impulse (physics) Condensed Matter Physics Electronic Optical and Magnetic Materials Conductor Magnetic field Electromagnetic coil Physics::Accelerator Physics Waveform Electrical and Electronic Engineering Electrical conductor |
Zdroj: | Publons |
ISSN: | 1558-2515 1051-8223 |
DOI: | 10.1109/77.233742 |
Popis: | The ramp-rate limitation found in the US-demonstration poloidal coil (US-DPC) test was studied in a laboratory scale experiment. The ramp-rate sensitivity has been identified on a 27-strand cable-in-conduit conductor at a background ramped field to 9.5 T with various ramp rates of 0.5 T/s to 2 T/s, simulating the US-DPC test conditions. A model assuming the existence of periodic disturbances is proposed in which the disturbance frequency is directly proportional to the ramp rate of the square of field. A semi-empirical formula was developed which fits the ramp-rate limitation data of both the US-DPC large coil and the 27-strand cable. The ramp-rate limitation does not occur for currents below the conventional limiting current. > |
Databáze: | OpenAIRE |
Externí odkaz: |