Popis: Objective: To compare the incidence of sternal wound dehiscence between simple interrupted vs. figure-of-eight sternal closure techniques for median sternotomy in patients undergoing coronary artery bypass graft surgery. Study Design: Comparative prospective, randomized control trial. Place and Duration of Study: Study conducted at Department of Cardiac Surgery, Armed Forces Institute of Cardiology Rawalpindi, from Apr to Dec 2019. Methodology: A total of 206 patients were included in study. These patients were divided into two groups; group “A”: cases which will undergo simple interrupted sternal wire closure technique (n1=103). Group “B”: cases which will undergo figure-of-eight sternal wire closure technique (n2 = 103). Results: There were no statistical difference in the pre-operative data of the patients. The incidence of sternal wound dehiscence in simple interrupted closure was 6.79% while in figure of eight closure technique it was noted to be 1.94%. A statistically significant difference was noted in both the closure technique (p