Investigation of Olive Mill Wastewater Treatment with Advanced Oxidation Processes
Autor: | Sinan Kul, İbrahim Cengiz, Fatma Ekmekyapar Torun |
---|---|
Rok vydání: | 2020 |
Předmět: |
chemistry.chemical_compound
Environmental Engineering Ozone Çevre Mühendisliği chemistry Wastewater Fenton (Fe²⁺+H₂O₂) hydrogen peroxide (H₂O₂) advanced oxidation process (AOP) ozone (O₃) olive mill wastewater Fenton (Fe²⁺+H₂O₂) hidrojen peroksit (H₂O₂) ileri oksidasyon prosesi (İOP) ozon (O₃) zeytin karasuyu Hydrogen peroxide Ozone generator Olive oil Nuclear chemistry |
Zdroj: | Volume: 10, Issue: 3 1597-1606 Journal of the Institute of Science and Technology |
ISSN: | 2536-4618 2146-0574 |
Popis: | Bu çalışmada, Balıkesir ilinde faaliyet gösteren bir zeytinyağı üretim tesisinden temin edilen zeytin karasuyunun arıtımında ozon (O3), ozon+hidrojen peroksit (O3+H2O2) ve fenton (Fe2++H2O2) proseslerinin etkinlikleri incelenmiştir. İlk olarak %10 kapasite ile O3 jeneratörü çalıştırılmış ve 3 farklı pH (4.75, 10 ve 11) değerinde 6 saat boyunca ozonlama işlemi gerçekleştirilmiş ve maksimum giderim verimi pH değeri 11 olarak ayarlandığında %15.27 olarak hesaplanmıştır. İkinci olarak %10 kapasite ile O3 jeneratörü çalıştırılmış ve ortama 500 mg L-1 H2O2 ilave edilmiştir. 6 saatlik bu deneme sonrasında giderim verimi %9.8 olarak gerçekleşmiştir. Son olarak zeytin karasuyunun arıtımı için farklı Fe2+ (2.014 g L-1 ve 4.028 g L-1) ve H2O2 (19.05, 44.44 ve 80 g L-1) konsantrasyonlarının etkilerinin incelendiği fenton prosesinde Fe2+ ve H2O2 konsantrasyonları arttığında deney sonunda ortamda kalan KOİ konsantrasyonları sürekli azalmıştır. Fe2+ konsantrasyonu 4.029 mg L-1 ve H2O2 konsantrasyonu 80 mg L-1 olarak ayarlanmış ve %81.94 oranında KOİ giderimi sağlanmıştır. Elde edilen sonuçlar fenton prosesinin, diğer proseslerden çok daha fazla etkinliğinin olduğunu ortaya çıkarmıştır. In this study, the effectiveness of ozone (O3), ozone+hydrogen peroxide (O3+H2O2) and fenton (Fe2++H2O2) processes were investigated in the treatment of olive mill wastewater obtained from an olive oil production facility operating in Balıkesir province. Firstly, the ozone generator was operated with a 10% capacity. Ozonation was performed for 6 hours at three different pH values (4.75, 10 and 11) and the maximum removal efficiency was calculated as 15.27% when the pH value was 11. Secondly, the ozone generator was operated with a 10% capacity and an avarage of 500 mg L-1 H2O2 was added. After this 6 hour experiment, the removal efficiency was obtained as 9.8%. Finally, in the fenton process, where the effects of Fe2+ (2.014 g L-1 and 4.028 g L-1) and H2O2 (19.05, 44.44 and 80 g L-1) concentrations were examined for the treatment of olive mill wastewater, the remained concentrations of COD decreased continuously at the and of the experinent when Fe2+ and H2O2 concentrations increased. The concentrations of Fe2+ and the H2O2 were set at 4.029 mg L-1 and 80 mg L-1 respectively, and COD removal was achieved at the rate of 81.94%. The results obtained from the experiments revealed that the fenton process has much more effeciency than other processes. |
Databáze: | OpenAIRE |
Externí odkaz: |