Comprehensive comparison of MR image quality between intratympanic and intravenous gadolinium injection using 3D real IR sequences
Autor: | Yaru Sheng, Xilan Liu, Feng Wang, Ping Lu, Yan Sha, Yang Li, Zhongshuai Zhang, Mengxiao Liu |
---|---|
Rok vydání: | 2019 |
Předmět: |
Adult
Male Adolescent Image quality Gadolinium Contrast Media chemistry.chemical_element Inversion recovery Signal-To-Noise Ratio 03 medical and health sciences 0302 clinical medicine medicine Humans Endolymphatic Hydrops Endolymphatic hydrops 030223 otorhinolaryngology Meniere Disease Aged Aged 80 and over Injection Intratympanic business.industry Significant difference General Medicine Middle Aged medicine.disease Magnetic Resonance Imaging Otorhinolaryngology chemistry 030220 oncology & carcinogenesis Injections Intravenous Female Mr images Detection rate Nuclear medicine business |
Zdroj: | Acta Oto-Laryngologica. 139:659-664 |
ISSN: | 1651-2251 0001-6489 |
DOI: | 10.1080/00016489.2019.1600719 |
Popis: | Background: Intratympanic and intravenous gadolinium administration is used to visualise endolymphatic hydrops. Aims/objectives: The goal of this study was to compare the image quality between intratympanic (IT-method) and intravenous (IV-method) gadolinium administration using three-dimensional inversion recovery with real reconstruction (3D real IR) sequences. Materials and methods: A number of 152 patients with Meniere's disease were included. The 3D real IR sequence was performed 24 h after IT administration or 4 h after IV administration. The detection rate of endolymphatic hydrops, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the two methods were compared. Specifically, the average image scores of the two methods were evaluated by two radiologists. Results: The SNRROI and CNRs of the IT-method were higher than those of the IV-method, whereas no significant difference between the IT-method and IV-method with regard to the SNRB was found. The average image scores were 3.49 ± 0.12 and 3.30 ± 0.12 for the IT-method and IV-method, respectively (p = .229). No statistically significant difference was found between two methods in terms of the detection rate of endolymphatic hydrops. Conclusions and significance: IT-method images can display endolymphatic hydrops more precisely than IV-method images. The IV-method can be used as an alternative to the IT-method in clinical applications to some extent. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |