Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure

Autor: Joseph Bartolo, Miruna Dobre, Fredrik Arrhén, Thomas Konczak, Mercede Bergoglio, Lovorka Grgec Bermanec, Adam Brzozowski, Yasin Durgut, Nieves Medina, Paul Hetherington, Jan van Geel, Sanja Burzić, Christian Wuethrich, Csilla Vámossy, Oliver Ott, Dietmar Steindl, Peter Farar, Alen Bošnjaković, I. Sandu, Sari Saxholm, Wladimir Sabuga, Bernard Waller, Antoine Condereys, I. Koçaş, Janez Šetina, Aykurt Altlntaş
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Zdroj: Altlntaş, A, Koçaş, I, Durgut, Y, Bartolo, J, Bergoglio, M, Bermanec, L G, Bošnjaković, A, Burzić, S, Condereys, A, Dobre, M, Farar, P, Hetherington, P, Medina, N, Sabuga, W, Ott, O, Konczak, T, Sandu, I, Setina, J, Steindl, D, Vámossy, C, Waller, B, Wuethrich, C, Brzozowski, A, Geel, J V, Saxholm, S & Arrhén, F 2020, ' Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure ', Metrologia, vol. 57, no. 1, 07022 . https://doi.org/10.1088/0026-1394/57/1A/07022
DOI: 10.1088/0026-1394/57/1A/07022
Popis: A EURAMET key comparison of the national pressure standards in the range 0.7 MPa to 7.0 MPa of gas gauge pressure was carried out. The circulation of the transfer standard began in November 2011 and lasted until November 2016. The measurand of the comparison was the effective area of the piston-cylinder assembly determined by gauge pressure measurements in the range from 0.7 MPa to 7.0 MPa. As the comparison reference value, the weighted mean of the results of the laboratories with primary pressure standards was used. With this reference value, all the participants who delivered the results demonstrated equivalence respective to the reference value within expanded uncertainties (k = 2) on all the range. The results of this comparison were linked to CCM key comparison CCM.P-K1.c. Also in relation to the reference values of CCM.P-K1.c, all participants demonstrated agreement within expanded uncertainties (k = 2) at all pressure points. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Databáze: OpenAIRE