Failure modes in electricity and telecommunication facilities in dwellings in Spain

Autor: Manuel J. Carretero-Ayuso, Jaime González-Domínguez, Justo García-Sanz-Calcedo, Gonzalo Sánchez-Barroso
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Technology
Computer science
QH301-705.5
media_common.quotation_subject
QC1-999
design faults
España
0211 other engineering and technologies
020101 civil engineering
construction faults
02 engineering and technology
Fault (power engineering)
Instalación de telecomunicaciones
Patologías - Construcción
0201 civil engineering
Project engineering
3305.01 Diseño Arquitectónico
021105 building & construction
Instalación de electricidad
General Materials Science
Quality (business)
fault modes
Edificación residencial
Biology (General)
Instrumentation
QD1-999
media_common
Fluid Flow and Transfer Processes
business.industry
Process Chemistry and Technology
Physics
General Engineering
3306.99 Otras
Diseño arquitectónico
Engineering (General). Civil engineering (General)
Computer Science Applications
3305.14 Viviendas
Chemistry
facilities
project engineering
3311.02 Ingeniería de Control
dwelling projects
3325.99 Otras
Electricity
Inspección de edificios
TA1-2040
Telecommunications
business
Zdroj: Applied Sciences
Volume 11
Issue 11
Applied Sciences, Vol 11, Iss 5274, p 5274 (2021)
Popis: The value of a house depends not only on the quality of the construction elements but also on the functionality of its installations. Making mistakes during the design and even execution phases of installations in newly built homes is common. This paper determines, catalogues, and quantifies faults in electrical and telecommunications installations in dwellings based on owners' complaints and using the "˜learning from faults' philosophy. To this end, 154 complaints concerning these installations in all of Spain were analyzed and protocolized. The results show that, in all types of dwellings, the most common fault was "˜alterations and malfunctions' (81%), followed by "˜incorrect or lack of placement of elements' (14%). The pathological origin with the greatest presence in the research was "˜shortcomings and omissions in the installation' (40%) and "˜anomalies in the installation' (36%). Moreover, all functional deterioration processes as well as the type of dwelling where each of these parameters occurred most were defined and quantified (association between each fault and its cause). Finally, the "˜probability factor' (PF) was determined, which numerically quantifies the probable existence of complaints according to four ranges. The results will pave the way for more precise inspections during the construction phase. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.