Failure modes in electricity and telecommunication facilities in dwellings in Spain
Autor: | Manuel J. Carretero-Ayuso, Jaime González-Domínguez, Justo García-Sanz-Calcedo, Gonzalo Sánchez-Barroso |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Technology
Computer science QH301-705.5 media_common.quotation_subject QC1-999 design faults España 0211 other engineering and technologies 020101 civil engineering construction faults 02 engineering and technology Fault (power engineering) Instalación de telecomunicaciones Patologías - Construcción 0201 civil engineering Project engineering 3305.01 Diseño Arquitectónico 021105 building & construction Instalación de electricidad General Materials Science Quality (business) fault modes Edificación residencial Biology (General) Instrumentation QD1-999 media_common Fluid Flow and Transfer Processes business.industry Process Chemistry and Technology Physics General Engineering 3306.99 Otras Diseño arquitectónico Engineering (General). Civil engineering (General) Computer Science Applications 3305.14 Viviendas Chemistry facilities project engineering 3311.02 Ingeniería de Control dwelling projects 3325.99 Otras Electricity Inspección de edificios TA1-2040 Telecommunications business |
Zdroj: | Applied Sciences Volume 11 Issue 11 Applied Sciences, Vol 11, Iss 5274, p 5274 (2021) |
Popis: | The value of a house depends not only on the quality of the construction elements but also on the functionality of its installations. Making mistakes during the design and even execution phases of installations in newly built homes is common. This paper determines, catalogues, and quantifies faults in electrical and telecommunications installations in dwellings based on owners' complaints and using the "˜learning from faults' philosophy. To this end, 154 complaints concerning these installations in all of Spain were analyzed and protocolized. The results show that, in all types of dwellings, the most common fault was "˜alterations and malfunctions' (81%), followed by "˜incorrect or lack of placement of elements' (14%). The pathological origin with the greatest presence in the research was "˜shortcomings and omissions in the installation' (40%) and "˜anomalies in the installation' (36%). Moreover, all functional deterioration processes as well as the type of dwelling where each of these parameters occurred most were defined and quantified (association between each fault and its cause). Finally, the "˜probability factor' (PF) was determined, which numerically quantifies the probable existence of complaints according to four ranges. The results will pave the way for more precise inspections during the construction phase. © 2021 by the authors. Licensee MDPI, Basel, Switzerland. |
Databáze: | OpenAIRE |
Externí odkaz: |