Evacuation Technique of Left-Sided Inferior Vena Cava for a Successful Open Repair of a Large Juxtarenal Aortic Aneurysm

Autor: Kalliopi Dimitrakopoulou, Stavros K. Kakkos, Paraskevi G. Apostolopoulou, Peter Zampakis, Christina Kalogeropoulou, Ioannis Ntouvas
Rok vydání: 2021
Předmět:
Zdroj: Vascular Specialist International, Vol 37, Iss 1, Pp 41-45 (2021)
Vascular Specialist International
ISSN: 2288-7989
2288-7970
DOI: 10.5758/vsi.200073
Popis: We report a case of successful open repair of a 7.5-cm juxtarenal abdominal aortic aneurysm (AAA) in the presence of a left-sided inferior vena cava (LS-IVC) crossing the aorta at the level of the renal arteries in a 72-year-old man. The orifice of the right renal artery was slightly caudal to that of the left renal artery and concomitant occlusive diseases of both iliac arteries were present. Based on the imaging and intraoperative findings, repair of the juxtarenal AAA was performed with mobilization of the LS-IVC, which was encircled twice with soft silicone rubber vessel loops on both sides of operating field and the blood content of the LS-IVC was temporarily evacuated. This procedure allowed proximal control with inter-renal clamping of the aorta and placement of an aortobifemoral polytetrafluoroethylene graft.