741-3 Prevention of Subacute Occlusion After Coronary Stenting with Ticlopidine Regimen without Intravascular Ultrasound Guided Stenting
Autor: | Bertrand Comet, Jean-L. Bouvier, Marc Silvestri, Jean-B. Siméoni, Gilles Bayet, Paul Barragan, Joel Sainsous |
---|---|
Rok vydání: | 1995 |
Předmět: |
medicine.medical_specialty
Blood transfusion medicine.diagnostic_test business.industry medicine.medical_treatment equipment and supplies medicine.disease Balloon Surgery Stenosis Regimen surgical procedures operative Coronary stent Intravascular ultrasound Occlusion medicine cardiovascular diseases Radiology Ticlopidine business Cardiology and Cardiovascular Medicine medicine.drug |
Zdroj: | Journal of the American College of Cardiology. 25(2) |
ISSN: | 0735-1097 |
DOI: | 10.1016/0735-1097(95)92214-p |
Popis: | Intravascular ultrasound (IVUS) guiding optimal coronary stent expansion has been proposed in the prevention of subacute stent thrombosis (SIT) wich remains the major limitation of coronary stenting. However this strategy, requiring high balloon pressure, enhances the risk of coronary rupture, and increases the time of procedure. We report our experience of coronary stenting using quantitative coronary analysis (OCA) and ticlopidine regimen (500 mg/day) initiated 3 days before PTCA and given for one month after stenting without any anticoagulation. From March 1994 to July 1994 among 587 consecutive PTCA, 208 patients (63 ± 11 yrs) were successfully stented on 235 lesions with 248 stents (223 Palmaz-Schatz, 25 Gianturco-Roubin). Femoral approach was used in 98% of cases with 8F (65%) or 6F guiding catheter (35%). Indications for stenting were elective (70%) or after failed PTCA(30%). The stents were expanded with a non compliant balloon (final diameter = 3.46 ± 0.42 mm) at 10 bars. OCA results were: Before stenting Aftar stenting Reference diameter (mm) 3.02 ± 042 321 ± 051 Minimal luminal diameter (mm) 095 ± 048 2.79 ± 0.60 * Diameter stenosis (%) 68 ± 15 13 ± 9 * Area stenosis (%) 88 ± 9 25 ± 16 * * p l 0.001 One month major complications included 2 deaths (0.96%). 2 O-wave MI (0.96%) and 1 emergency CABG (0.5%). SST during the first month occured in 1 pt (0.5%). One pt (0.5%) required external compression for false aneurism and one (0.5%) blood transfusion for gastric hemorrhage. Conclusion Pre and post coronary stenting treatment with ticlopidine regimen provides low rate of SST with acceptable vascular bleeding complications. Routine IVUS utility with this regimen remains uncertain. |
Databáze: | OpenAIRE |
Externí odkaz: |