Lack of reliability of nanotechnology in the of free plasma DNA in samples of patients with prostate cancer

Autor: Ligia Ajaime Azzalis, Viviane Av Boas, Virginia Bc Junqueira, Jefferson Drezzet, Katya Cristina Rocha, Luiz Carlos de Abreu, Sarah R Marsicano, Edimar Cristiano Pereira, Pamela de Oliveira Delgado, Ricardo Moreno, Fernando La Fonseca, Patricia Granja Coelho, Vitor Engrácia Valenti
Přispěvatelé: Faculdade de Medicina do ABC (FMABC), Universidade Federal de São Paulo (UNIFESP), Universidade Estadual Paulista (Unesp)
Jazyk: angličtina
Rok vydání: 2013
Předmět:
Zdroj: Scopus
Repositório Institucional da UNESP
Universidade Estadual Paulista (UNESP)
instacron:UNESP
International Archives of Medicine
Popis: Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-27T11:28:10Z No. of bitstreams: 0Bitstream added on 2014-05-27T14:37:13Z : No. of bitstreams: 1 2-s2.0-84872131878.pdf: 264619 bytes, checksum: f1b166deaa25d9ab41c2fc74bbd08163 (MD5) Made available in DSpace on 2014-05-27T11:28:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-01-16 Background: Several studies seek biological markers that give diagnostic and degree of tumor development. The aim of this study was to validate the determination of plasma DNA using nanotechnology (Nanovue™-NV) in samples of 80 patients with prostate cancer. Methods. Blood samples of 80 patients of the Urology Ambulatory of Faculdade de Medicina do ABC with prostate cancer confirmed by anatomical-pathology criteria were analyzed. DNA extraction was performed using a GFX TM kit (Amersham Pharmacia Biotech, Inc, USA) following the adapted protocol. Plasma was subjected to centrifugation. Results: There was a big difference between the first and the second value obtained by NanoVue Only two samples had no differences between duplicates. Maximum difference between duplicates was 38 μg/mL. Average variation between 51 samples was 10.29 μg/mL, although 21 samples had differences above this average. No correlation was observed between pDNA obtained by traditional spectrophotometry and by nanotechnology. Conclusion: Determination of plasma DNA by nanotechnology was not reproducible. © 2013 Moreno et al; licensee BioMed Central Ltd. Laboratório de Análises Clínicas Faculdade de Medicina Do ABC, Av. Príncipe de Gales 821, Santo André, CEP: 09060-650 Departamento de Ciências Biológicas Universidade Federal de São Paulo UNIFESP, Rua Prof. Artur Riedel, 275, Diadema, São Paulo 09972-270 Laboratório de Delineamento de Estudos e Escrita Científica Departamento de Morfologia e Fisiologia Faculdade de Medicina Do ABC, Santo André, Av. Príncipe de Gales, n. 821, Santo André, CEP: 09060-650 Programa de Pós-Graduação em Fisioterapia Faculdade de Ciências e Tecnologia Universidade Estadual Paulista, Rua Roberto Simonsen, 305, Presidente Prudente, São Paulo 19060-900 Programa de Pós-Graduação em Fisioterapia Faculdade de Ciências e Tecnologia Universidade Estadual Paulista, Rua Roberto Simonsen, 305, Presidente Prudente, São Paulo 19060-900
Databáze: OpenAIRE