Combined Current Profiling and Biological Echosounding Results from a Single ADCP
Autor: | Terje Pettersen, David W. Velasco, Sven Nylund |
---|---|
Rok vydání: | 2018 |
Předmět: |
0106 biological sciences
Nàutica::Navegació marítima::Instrumentació i equipament per a la navegació [Àrees temàtiques de la UPC] Doppler navigation Frequency band Acoustics Echosounding Comunicacions subacuàtiques Doppler Efecte 01 natural sciences Acoustic Doppler current profiler Echo sounding Currents Underwater acoustics 0502 economics and business Chirp Biomass Center frequency Acústica submarina Física::Acústica [Àrees temàtiques de la UPC] Dynamic range 010604 marine biology & hydrobiology 05 social sciences ADCP Pulse compression 050202 agricultural economics & policy Beam (structure) Geology |
Zdroj: | Instrumentation viewpoint; 2018: Núm.: 20 UPCommons. Portal del coneixement obert de la UPC Universitat Politècnica de Catalunya (UPC) |
ISSN: | 1697-2562 1886-4864 |
DOI: | 10.1109/oceanskobe.2018.8559356 |
Popis: | The present work describes a newly-developed Acoustic Doppler Current Profiler (ADCP) that has a fully integrated single-beam wide-band biological echosounder, thus serving a dual purpose: current measurement and biomass assessment. The system comprises a traditional 4-beam Janus configuration head, which is responsible for profiling the currents, with a vertically oriented center beam for collecting high-resolution acoustic backscatter data for subsequent biomass analysis. The system belongs to the Signature Series family of ADCPs launched in 2013 by Norwegian scientific instrumentation company Nortek. Named Signature100, it is powered by the AD2CP electronics platform, described in United States Patent 7.911.880. The four slanted beams (current profiling beams) operate at a center frequency of 100 kHz and have a range of up to 400 m with 4 m spatial resolution and sampling rate up to 1 Hz. The center vertical beam (echosounding beam) has a wider frequency band of approximately 70-120 kHz with a high dynamic range (~130 dB), and presently operating in up to three discreet pulse characteristics from a single beam set: 1) 70 kHz monochromatic, 2) 120 kHz monochromatic, and 3) 91 kHz chirp with 50 percent bandwidth and pulse compression. Acoustic pulses from the echosounder beam are interweaved with pulses for the current profiling beam for synchronous data collection. In this work we describe the system’s configuration, capabilities and results from initial trials.paper that is identical with the extended summaries format. |
Databáze: | OpenAIRE |
Externí odkaz: |