Evaluating adhesion reduction efficacy of type I/III collagen membrane and collagen-GAG resorbable matrix in primary flexor tendon repair in a chicken model
Autor: | Rubina L. Corazzini, Brian Rinker, John Brad Turner, David S. Garlick, Timothy J. Butler |
---|---|
Rok vydání: | 2015 |
Předmět: |
Surgery Articles
medicine.medical_specialty business.industry medicine.medical_treatment Collagen membrane Adhesion (medicine) Adhesion barrier Matrix (biology) musculoskeletal system medicine.disease Tendon Surgery Plastic surgery medicine.anatomical_structure medicine Orthopedics and Sports Medicine business Primary flexor tendon repair Reduction (orthopedic surgery) Biomedical engineering |
Zdroj: | Hand (New York, N.Y.). 10(3) |
ISSN: | 1558-9447 |
Popis: | Background Reduction of peritendinous adhesions after injury and repair has been the subject of extensive prior investigation. The application of a circumferential barrier at the repair site may limit the quantity of peritendinous adhesions while preserving the tendon's innate ability to heal. The authors compare the effectiveness of a type I/III collagen membrane and a collagen-glycosaminoglycan (GAG) resorbable matrix in reducing tendon adhesions in an experimental chicken model of a “zone II” tendon laceration and repair. Methods In Leghorn chickens, flexor tendons were sharply divided using a scalpel and underwent repair in a standard fashion (54 total repairs). The sites were treated with a type I/ III collagen membrane, collagen-GAG resorbable matrix, or saline in a randomized fashion. After 3 weeks, qualitative and semiquantitative histological analysis was performed to evaluate the “extent of peritendinous adhesions” and “nature of tendon healing.” The data was evaluated with chi-square analysis and unpaired Student's t test. Results For both collagen materials, there was a statistically significant improvement in the degree of both extent of peritendinous adhesions and nature of tendon healing relative to the control group. There was no significant difference seen between the two materials. There was one tendon rupture observed in each treatment group. Surgical handling characteristics were subjectively favored for type I/III collagen membrane over the collagen-GAG resorbable matrix. Conclusion The ideal method of reducing clinically significant tendon adhesions after injury remains elusive. Both materials in this study demonstrate promise in reducing tendon adhesions after flexor tendon repair without impeding tendon healing in this model. |
Databáze: | OpenAIRE |
Externí odkaz: |