Determination of arsenic chemical species in rice grains using high-performance liquid chromatography coupled to hydride generator with atomic fluorescence detector (HPLC-HG-AFS)

Autor: José Marrugo-Negrete, Germán Enamorado-Montes, Luis Ángel Ospina Herrera, Iván Urango-Cárdenas, Saudith Burgos-Núñez
Rok vydání: 2020
Předmět:
Analytical validation
Science
Clinical Biochemistry
chemistry.chemical_element
(LOD)
Limits of detection

(LOQ)
Limits of quantification

010501 environmental sciences
01 natural sciences
High-performance liquid chromatography
03 medical and health sciences
chemistry.chemical_compound
HPLC-HG-AFS
High-performace liquid chromatography coupled to hydride generator with atomic fluorescence detector

arsenic species by HPLC-HG-AFS in rice grain
LGS
liquid gas separator

Arsenic
030304 developmental biology
0105 earth and related environmental sciences
Arsenite
Detection limit
0303 health sciences
Reproducibility
Chromatography
Chemistry
As (III)
arsenite

Anion exchange chromatography
Extraction (chemistry)
Arsenate
As (V)
arsenate

food and beverages
Repeatability
Cereal grain
Method Article
Medical Laboratory Technology
MMA
monomethylarsonic acid

MAE
microwave assisted extraction

DMA
dimethylarsinic acid
Zdroj: MethodsX
MethodsX, Vol 8, Iss, Pp 101281-(2021)
ISSN: 2215-0161
Popis: The objective of this work is the validation and implementation of an analytical method for the determination of arsenic chemical species in rice grain samples using High-performance liquid chromatography coupled to a hydride generator with atomic fluorescence detector (HPLC-HG-AFS). The extraction protocol developed was based on HNO3 0.28 M (90 °C, 2 h), microwave-assisted. The results showed recovery percentages of arsenite (As (III)) (99–101%), arsenate (As (V)) (91–96%), dimethylarsinic acid (DMA) (92–102%) and monomethylarsonic acid (MMA) (94–97%). The precision of the method presented coefficients of variation lower than 7% and 8% for repeatability and reproducibility respectively. The detection limits were 2.5, 3.75, 7.5 and 4.0 µg kg−1 for As (III), As (V), DMA and MMA respectively. The proposed methodology is reliable for the quantification of As species, because they are conserved during the extraction.•The extraction protocol developed was based on Microwave-assisted acid extraction.•This methodology offers good sensitivity, precision, accuracy, detection and quantification limits.•It was successfully applied to determination of arsenic chemical species in rice grains.
Graphical abstract Image, graphical abstract
Databáze: OpenAIRE