The Diagnostic Value of Hepatic Pliability as Assessed from Inspiration and Expiration Views on the Gamma Camera
Autor: | Francis H. Straus, Robert E. Polcyn, Alexander Gottschalk, Paul V. Harper, Jeanette M. Vollert, Jeffery K. Kranzler |
---|---|
Rok vydání: | 1970 |
Předmět: |
medicine.medical_specialty
Biopsy Tissue Adhesions Adenocarcinoma law.invention law Humans Medicine Radiology Nuclear Medicine and imaging Colloids Expiration Full expiration Radionuclide Imaging Gamma camera Pliability business.industry Liver Diseases Respiration Liver Neoplasms Technetium Anger Camera Liver Leukemia Myeloid Autopsy Radiology Abnormality business Nuclear medicine Liver pathology |
Zdroj: | Radiology. 97:323-326 |
ISSN: | 1527-1315 0033-8419 |
DOI: | 10.1148/97.2.323 |
Popis: | With use of multimillicurie amounts of technetium-99tn colloid and the Anger camera, anterior views of the liver can be produced with about 100,000 counts in twenty seconds or less. If obtained in full expiration and inspiration, these show change in hepatic shape or pliability. Among the authors' series of 75 proved cases, lack of pliability reliably indicated abnormality. |