Advantages and disadvantages of different nasal CPAP systems in newborns
Autor: | Maja I. Hug, Bernhard Frey, Oskar Baenziger, V. Buettiker, Christian Meyer |
---|---|
Přispěvatelé: | University of Zurich, Buettiker, V |
Jazyk: | angličtina |
Rok vydání: | 2018 |
Předmět: |
medicine.medical_specialty
medicine.medical_treatment Birth weight 610 Medicine & health Gestational Age Nose Critical Care and Intensive Care Medicine 142-005 142-005 Infant Newborn Diseases law.invention Randomized controlled trial law Intensive care Intensive Care Units Neonatal Medicine Birth Weight Humans Continuous positive airway pressure Continuous Positive Airway Pressure business.industry Infant Newborn Gestational age medicine.disease Surgery Exact test Low birth weight Pneumothorax Anesthesia medicine.symptom business 2706 Critical Care and Intensive Care Medicine |
Popis: | Objective: To compare three different systems of continuous positive airway pressure (CPAP): the naso-pharyngeal tube and two-prong systems in newborns, focusing on duration of CPAP, side effects and cost. Design: Randomized clinical study. Patients: Between July 2000 and September 2001 newborns were randomized to three different CPAP systems. Forty infants in two weight groups (>2500g and 1250-2500g; 20 patients in each group) were included. Results: In the group >2500g the median duration of CPAP was 1.1days (range 0.25-14.3days). The median time on a naso-pharyngeal CPAP was 1day (range 0.25-14.3days), on Hudson prongs 1.6days (range 0.5-3.3days) and on the Infant Flow system 0.7days (range 0.3-13.6days; p>0.05 for comparison between groups, Fisher's exact test). With naso-pharyngeal CPAP, 2 patients developed moderate nasal injuries. On Hudson, 2 patients developed moderate and three mild nasal injuries. One patient on the Infant Flow showed mild and one moderate nasal injuries. In the weight group 1250-2500g the median duration of CPAP was 1.1days (range 0.1-7.0days). The median time on the naso-pharyngeal tube was 0.9days (range 0.1-7days), on Hudson prongs 1.1days (range 0.7-6.6days) and on the Infant Flow system 1.3days (range 0.25-5.9days; p>0.05 for comparison between groups, Fisher's exact test). With a naso-pharygeal tube, one infant developed mild and one moderate nasal injuries. On Hudson prongs, two had moderate nasal injuries. On Infant Flow, one newborn showed a severe nasal injury and two mild injuries. None of the patients developed a pneumothorax. Conclusion: The naso-pharyngeal tube is an easy, safe and economical CPAP system usable with every common ventilator. For very low birth weight newborns, a prong system may have advantages |
Databáze: | OpenAIRE |
Externí odkaz: |