A simple method for 3D lesion reconstruction from two projected angiographic images: implementation to a stereotactic radiotherapy treatment planning system
Autor: | J.C. Rosenwald, Kiki Theodorou, C. Kappas, G. Gaboriaud, A.D. Mazal, O. Petrascu |
---|---|
Rok vydání: | 1997 |
Předmět: |
Intracranial Arteriovenous Malformations
medicine.medical_specialty Modality (human–computer interaction) medicine.diagnostic_test business.industry medicine.medical_treatment Radiotherapy Planning Computer-Assisted 3D reconstruction Hematology Radiosurgery Visualization Cerebral Angiography Oncology Feature (computer vision) Angiography medicine Image Processing Computer-Assisted Humans Regression Analysis Radiology Nuclear Medicine and imaging Tomography Radiology business Nuclear medicine Radiation treatment planning |
Zdroj: | Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 43(3) |
ISSN: | 0167-8140 |
Popis: | Introduction : The most used imaging modality for diagnosis and localisation of arteriovenous malformations (AVMs) treated with stereotactic radiotherapy is angiography. The fact that the angiographic images are projected images imposes the need of the 3D reconstruction of the lesion. This, together with the 3D head anatomy from CT images could provide all the necessary information for stereotactic treatment planning. We have developed a method to combine the complementary information provided by angiography and 2D computerized tomography, matching the reconstructed AVM structure with the reconstructed head of the patient. Materials and methods : The ISIS treatment planning system, developed at Institute Curie, has been used for image acquisition, stereotactic localisation and 3D visualisation. A series of CT slices are introduced in the system as well as two orthogonal angiographic projected images of the lesion. A simple computer program has been developed for the 3D reconstruction of the lesion and for the superposition of the target contour on the CT slices of the head. Results and conclusions : In our approach we consider that the reconstruction can be made if the AVM is approximated with a number of adjacent ellipses. We assessed the method comparing the values of the reconstructed and the actual volumes of the target using linear regression analysis. For treatment planning purposes we overlapped the reconstructed AVM on the CT slices of the head. The above feature is to our knowledge a feature that the majority of the commercial stereotactic radiotherapy treatment planning system could not provide. The implementation of the method into ISIS TPS shows that we can reliably approximate and visualize the target volume. |
Databáze: | OpenAIRE |
Externí odkaz: |