The impact of pre-implant illness severity on the outcomes of pediatric patients undergoing durable ventricular assist device
Autor: | Philip T. Thrush, Minmin Lu, Joseph W. Rossano, Lynn A. Sleeper, Sarah A. Teele, Ryan S. Cantor, Joseph Philip, Arene Butto |
---|---|
Rok vydání: | 2019 |
Předmět: |
Pulmonary and Respiratory Medicine
Male medicine.medical_specialty Heart disease Adolescent medicine.medical_treatment Population Cardiomyopathy 030204 cardiovascular system & hematology Severity of Illness Index 03 medical and health sciences Young Adult 0302 clinical medicine Internal medicine Medicine Humans Registries Risk factor education Child Retrospective Studies Heart Failure Transplantation education.field_of_study business.industry Cardiogenic shock Hazard ratio Infant medicine.disease Treatment Outcome 030228 respiratory system Heart failure Ventricular assist device Child Preschool Cardiology Surgery Female Heart-Assist Devices Cardiology and Cardiovascular Medicine business Follow-Up Studies |
Zdroj: | The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 39(7) |
ISSN: | 1557-3117 |
Popis: | Durable ventricular assist devices (VADs) are increasingly used to treat children with heart failure. Studies demonstrate worse outcomes for those in cardiogenic shock at the time of VAD, but limited data exist on less acutely ill children. We describe the association between illness severity and outcomes in this population.Data were analyzed from 373 children (aged19 years) receiving durable VADs from 46 centers in the Pediatric Interagency Registry for Mechanical Circulatory Support. Outcomes were compared by Interagency Registry for Mechanical Circulatory Support (INTERMACS) Patient Profile (PP) and pre-implant characteristics using competing risks methodology.Analyses identified 97 patients in cardiogenic shock (PP 1), 222 with progressive decline (PP 2), and 42 stable on inotropes (PP 3). There were 39 infants, 124 were aged 1 to 9 years and 210 were aged 10 to 19 years. A majority had cardiomyopathy and 66 had congenital heart disease (CHD). There were 224 (62%) continuous-flow VADs. Before implant, 40% received mechanical ventilation (MV). Within 6 months post-implant, 57% underwent transplant and 14% died. PP 1 mortality was highest (25% vs 10% for PP 2, hazard ratio [HR]: 2.5, 95% CI: 1.4-4.4, p = 0.02). In PP 1, CHD was an independent mortality risk factor (HR: 2.9, 95% CI: 1.1-7.8, p = 0.03). In PP 2, pulsatile VADs were associated with death (HR: 3.9, 95% CI: 1.6-9.5, p = 0.003). Patients on MV had high mortality (20%-30%) across PP 1 to PP 3 (HR: 3.0 vs no MV, p0.001).Children in shock at the time of VAD implant have poor outcomes. MV is associated with increased mortality even in lower acuity INTERMACS profiles. Further study is needed to identify modifiable risk factors in this population. |
Databáze: | OpenAIRE |
Externí odkaz: |