Validação da Versão Brasileira do Questionário de Triagem do Transtorno Comportamental do Sono REM (QT-TCSREM-BR)
Autor: | Manoel Alves Sobreira-Neto, Carolina Pinto Souza, Regina Maria França Fernandes, Emmanuelle Silva Tavares Sobreira, Márcio Alexandre Pena-Pereira, Alan Luiz Eckeli, Daniel Sabino de Oliveira, Marcos Hortes Nisihara Chagas, Guilherme Riccioppo Rodrigues, Vitor Tumas |
---|---|
Rok vydání: | 2020 |
Předmět: |
medicine.medical_specialty
Intraclass correlation Polysomnography Neurosciences. Biological psychiatry. Neuropsychiatry REM Sleep Behavior Disorder REM sleep behavior disorder Parkinson’s Disease 03 medical and health sciences 0302 clinical medicine Cronbach's alpha Surveys and Questionnaires Internal medicine medicine Humans Mass Screening 030212 general & internal medicine Mass screening Receiver operating characteristic medicine.diagnostic_test business.industry Brasil Area under the curve Gold standard (test) medicine.disease Transtorno do Comportamento do Sono REM Polissonografia Neurology QUESTIONÁRIOS Inquéritos e Questionários Neurology (clinical) Doença de Parkinson business Brazil 030217 neurology & neurosurgery RC321-571 |
Zdroj: | Arquivos de Neuro-Psiquiatria, Volume: 78, Issue: 10, Pages: 629-637, Published: 28 OCT 2020 Repositório Institucional da USP (Biblioteca Digital da Produção Intelectual) Universidade de São Paulo (USP) instacron:USP Arquivos de Neuro-Psiquiatria v.78 n.10 2020 Arquivos de neuro-psiquiatria Academia Brasileira de Neurologia instacron:ABNEURO Arquivos de Neuro-Psiquiatria, Vol 78, Iss 10, Pp 629-637 (2020) |
ISSN: | 1678-4227 0004-282X |
DOI: | 10.1590/0004-282x20200125 |
Popis: | Introduction: A diagnosis of rapid eye movement sleep behavior disorder (RBD) currently requires confirmation with polysomnography (PSG). However, PSG may not be sufficiently available. In these situations, a clinical diagnostic measure might be useful. Objective: To validate the Brazilian Portuguese version of RBD screening questionnaire (RBDSQ) for patients with Parkinson’s disease (PD). Methods: Using detailed clinical interviews and PSG analysis (diagnostic gold standard), a convenience sample of 69 subjects was divided into the following subgroups: patients with PD and RBD (PD+RBD; n=50) and patients with PD alone (PD-RBD; n=19). Results: RBDSQ-BR showed adequate internal consistency (Cronbach’s α=0.809) and, except for item 8, adequate item-test correlation. The retest performed in a second sample (n=13, consecutive) showed high agreement for total score (intraclass correlation coefficient, ICC=0.863) and acceptable agreement for items 2, 3, 6.2, 6.3, 7, and 8 (K>0.60). The receiver operating characteristic (ROC) curve analysis had an area under the curve (AUC) of 0.728. A cut-off score of 4 enabled the correct diagnosis of 76.8% subjects and provided the best balance between sensitivity (84%) and specificity (57.9%), with a 2.0 likelihood ratio of a positive result (LR+) and a 0.3 likelihood ratio of a negative result (LR-). Items 2 and 6.2 had 84.2% specificity and 3.2 LR+. Combined items 1+2+6.2, 2+6.1, and 6.1+6.2 increased the specificity to 94.7%, with LR+ ranging from 6.1 to 7.6. Conclusions: RBDSQ-BR is a reliable instrument, which may be useful for RBD diagnosis of Brazilian patients with PD. The instrument is also valid and may help in a better selection of cases for a more detailed clinical evaluation or even PSG analysis. RESUMO Introdução: O diagnóstico do transtorno comportamental do sono REM (TCSREM) implica na realização da polissonografia (PSG), mas sua disponibilidade pode não ser suficiente. Portanto, meios clínicos para o diagnóstico podem ser úteis. Objetivo: Validar para a língua portuguesa falada no Brasil o questionário de triagem do TCSREM (QT-TCSREM) em pacientes portadores de doença de Parkinson (DP). Métodos: Uma amostra por conveniência composta de 69 indivíduos foi dividida em portadores de DP com TCSREM (n=50) e DP sem TCSREM (n=19) através de entrevista clínica detalhada e análise da PSG. Resultados: QT-TCSREM-BR apresentou consistência interna adequada (α de Cronbach=0,809) e, exceto pelo item 8, correlação item-total adequada. Reteste feito em uma segunda amostra (n=13, consecutivos) evidenciou concordância elevada para o escore total (coeficiente de correlação intraclasse, CCI=0,863) e aceitável para os itens 2, 3, 6.2, 6.3, 7 e 8 (K>0,60). Análise da curva característica de operação do receptor (COR) obteve uma área sob a curva de 0,728. O corte 4 permitiu o diagnóstico correto de 76,8% dos indivíduos e apresentou o melhor equilíbrio entre sensibilidade (84%) e especificidade (57,9%), com uma razão de verossimilhança de um resultado positivo (RV+) 2,0 e de um resultado negativo (RV-) 0,3. Os itens 2 e 6.2 obtiveram especificidade 84,2% e RV+ 3,2. Itens combinados 1+2+6,2, 2+6,1 e 6,1+6,2 aumentaram a especificidade para 94,7%, com RV+ variando de 6,1 até 7,6. Conclusões: O QT-TCSREM-BR é um instrumento confiável que pode ser útil para o diagnóstico do TCSREM em pacientes com DP no Brasil. O instrumento também é válido e pode auxiliar numa melhor seleção de casos a serem submetidos a uma avaliação mais detalhada ou até mesmo a uma análise de PSG. |
Databáze: | OpenAIRE |