European multi-centre comparison of thallium 201 and technetium 99m methoxyisobutylisonitrile in ischaemic heart disease

Autor: M. N. Khalil, J. B. van der Schoot, A. Bischof-Delaloye, A. Lowry, R. Fridrich, E. Inglese, Michael N. Maisey
Rok vydání: 1990
Předmět:
Zdroj: European journal of nuclear medicine. 16(12)
ISSN: 0340-6997
Popis: Fifty-six patients in Europe were entered into a multi-centre study to compare the accuracy of technetium 99m methoxyisobutylisonitrile (99mTc-MIBI) for the detection of coronary artery disease (CAD) with thallium 201 (201Tl) chloride perfusion scanning. The results showed a high degree of concordance between the two radiopharmaceuticals. Some 81% (678/840) of myocardial segments showed the same result (normal, infarct or ischaemia), and 80% (45/56) of patients had the same diagnosis. Overall detection of CAD in patients was 98% for 201T1 and 96% for 99mTc-MIBI. Detection of CAD in total arteries was 68% for both agents. In this study 99mTc-MIBI was as accurate as 201Tl for the detection of coronary artery stenoses.
Databáze: OpenAIRE