Thyroglobulin autoantibody levels below the cut-off for positivity can interfere with thyroglobulin measurement
Autor: | J. Rodríguez-Espinosa, R. Corcoy, C. Gelpi, J. M. Cubero, M. Estorch |
---|---|
Rok vydání: | 2003 |
Předmět: |
Adult
medicine.medical_specialty Thyrotoxicosis factitia Endocrinology Diabetes and Metabolism medicine.medical_treatment Thyroglobulin Endocrinology Recurrence Internal medicine medicine Humans Diagnostic Errors Antithyroglobulin antibody Volume concentration Autoantibodies Thyroglobulin Measurement biology business.industry fungi Osmolar Concentration Autoantibody food and beverages medicine.disease Graves Disease Thyrotoxicosis Immunology biology.protein Female Antibody business Artifacts |
Zdroj: | Thyroid : official journal of the American Thyroid Association. 13(7) |
ISSN: | 1050-7256 |
Popis: | Antithyroglobulin antibodies can interfere with the measurement of thyroglobulin yielding spuriously high or low levels depending on the method used. Interference is unrelated to the antibody concentration and can occur at very low concentrations. We report a patient in whom antithyroglobulin antibodies below the cut-off for positivity nearly led to an incorrect diagnosis of thyrotoxicosis factitia. |