Soft tissue around three different implant types after 1.5 years of functional loading without oral hygiene. A preliminary study in baboons
Autor: | Stefan Tangl, Karl Donath, Werner Zechner, Christoph Vasak, Georg Watzak, Georg Watzek |
---|---|
Rok vydání: | 2006 |
Předmět: |
Male
Time Factors Alveolar Bone Loss Dental Plaque Epithelial Attachment Connective tissue Dentistry Mandible Oral hygiene Acid Etching Dental Coated Materials Biocompatible Osseointegration Periodontal Attachment Loss Maxilla Mucositis Animals Periodontal Pocket Medicine Periodontitis Periodontal Diseases Dental Implants Titanium business.industry Soft tissue Oral Hygiene medicine.disease Confidence interval medicine.anatomical_structure Dental Prosthesis Design Connective Tissue Implant types Denture Partial Fixed Dental Prosthesis Implant-Supported Implant Oral Surgery business Papio |
Zdroj: | Clinical Oral Implants Research. 17:229-236 |
ISSN: | 1600-0501 0905-7161 |
Popis: | The purpose of this study was to determine the peri-implant soft tissue dimension (PSD) and peri-implant bone level (BL) of dental implants with different designs and surface modifications after functional loading without oral hygiene. Three types of dental implants were placed in the posterior jaws of adult baboons, three of the same design per quadrant, and fitted with fixed partial dentures. After 1.5 years of functional loading and plaque accumulation, all implants showed severe peri-implant mucositis and comparatively high BL. A histomorphometric evaluation of the sulcus depth (SD), the dimension of the junctional epithelium (JE) and the connective tissue contact (CTC) resulted in no significant differences between the three implant designs, neither in the maxilla nor in the mandible (P>0.05). The sum of SD, JE and CTC forming the PSD was nearly the same in the maxilla (commercially pure titanium, CpTi: 3.5 mm 2.9/4.1 confidence interval (CI); titanium plasma sprayed (TPS): 3.5 mm 2.9/4.2 CI; sand blasted acid-etched (GBAE): 3.2 mm 2.7/3.9 CI) and in the mandible (CpTi: 3.2 mm 2.6/3.8 CI; TPS: 3.2 mm 2.6/3.8 CI; GBAE: 3.2 mm 2.7/3.9 CI; P>0.05). There was no difference in BL around the three implant designs (maxilla: CpTi: 0.9 mm 0.5/1.6 CI; TPS: 0.9 mm 0.5/1.5CI; GBAE: 0.9 mm 0.5/1.6 CI; mandible: CpTi: 0.8 mm 0.5/1.2 CI; TPS: 0.6 mm 0.4/0.9 CI; GBAE: 0.7 mm 0.5/1.1 CI; P>0.05). Overall, the data presented did not show any significant differences in peri-implant soft tissue conditions in baboons. Moreover, plaque accumulation and propagation of peri-implant mucositis after 1.5 years of functional loading was not influenced by implant design and surface modifications in baboons. |
Databáze: | OpenAIRE |
Externí odkaz: |