Parathyroid scintigraphy with iodine-123 and 99mTc-sestamibi: imaging findings
Autor: | E F Binet, George J. Burke, J P Wei |
---|---|
Rok vydání: | 1993 |
Předmět: |
Adenoma
Technetium Tc 99m Sestamibi medicine.diagnostic_test business.industry Thyroid Subtraction General Medicine Scintigraphy 99mTc Sestamibi Sensitivity and Specificity Iodine Radioisotopes Parathyroid Glands Parathyroid scintigraphy medicine.anatomical_structure Parathyroid Neoplasms Iodine-123 medicine Humans Radiology Nuclear Medicine and imaging Parathyroid gland Nuclear medicine business Radionuclide Imaging Technetium-99m |
Zdroj: | AJR. American journal of roentgenology. 161(6) |
ISSN: | 0361-803X |
Popis: | Subtraction scintigraphy with 99mTc-pertechnetate and 201Tl-chloride is widely used for localizing the parathyroid gland, but the sensitivity of this method averages only 55%. The sensitivity of scintigraphy is improved by using a combination of 99mTc-sestamibi and iodine-123. Parathyroid adenomas can also be localized with 99mTc-sestamibi alone by subtracting early images from late sequential images. The fast washout of 99mTc-sestamibi from the thyroid gland allows visualization of the parathyroid gland. The purpose of this essay is to illustrate the findings of abnormalities of the parathyroid glands when using a combination of 99mTc-sestamibi and iodine-123. |