Determination of levodopa in human plasma by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS): application to a bioequivalence study

Autor: Douglas Pereira Pinto, C. Amendoeira, A. S. Marques, Heliana Figueiredo Martins, A. Nascimento
Rok vydání: 2013
Předmět:
Zdroj: Química Nova, Vol 36, Iss 1, Pp 171-176 (2013)
ISSN: 0100-4042
DOI: 10.1590/s0100-40422013000100028
Popis: A sensitive, accurate and simple method using HPLC-MS/MS was developed and validated for levodopa quantitation in human plasma. Analysis was achieved on a pursuit® C18 analytical column (5 µm; 150 x 4.6 mm i.d.) using a mobile phase (methanol and water , 90:10, v/v) containing formic acid 0.5% v/v, after extracting the samples using a simple protein plasma precipitation with perchloric acid. The developed method was validated in accordance with ANVISA guidelines and was successfully applied to a bioequivalence study in 60 healthy volunteers demonstrating the feasibility and reliability of the proposed method.