The First Tests on Vertical Cryostat GERSEMI at FREIA Facility

Autor: Thermeau, Jean-Pierre, Gajewski, Konrad, Hermansson, Lars, Junquera, Tomas, Kochebina, Olga, Ruber, Roger, Santiago Kern, Rocio
Přispěvatelé: AstroParticule et Cosmologie (APC (UMR_7164)), Observatoire de Paris, PSL Research University (PSL)-PSL Research University (PSL)-Université Paris Diderot - Paris 7 (UPD7)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS), Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Centre National de la Recherche Scientifique (CNRS)-Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Observatoire de Paris, PSL Research University (PSL)-PSL Research University (PSL)-Université Paris Diderot - Paris 7 (UPD7), Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Institut National de Physique Nucléaire et de Physique des Particules du CNRS (IN2P3)-Observatoire de Paris, Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Université de Paris (UP), Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Université Paris Cité (UPCité)
Jazyk: angličtina
Rok vydání: 2019
Předmět:
Zdroj: 19th International Conference on RF Superconductivity (SRF 2019)
19th International Conference on RF Superconductivity (SRF 2019), Jun 2019, Dresden, Germany. pp.THP034, ⟨10.18429/JACoW-SRF2019-THP034⟩
Popis: A new vertical cryostat, called Gersemi, installed at FREIA Laboratory at Uppsala University, Sweden, is designed to test superconducting magnets and radio-frequency cavities and operates at temperatures between 1.8 K and 4.2 K. Two different inserts can be used to test different superconducting equipment: a helium saturated bath insert for cavities without a helium vessel and a λ-plate insert for magnet testing in superfluid helium pressurized bath. The cold vessel cryostat has an internal diameter of 1.1 m and a useful height of 3.5 m. A valve box supplies the cryostat with the cryogens (LN2, LHe, SHe) and is linked to a gas reheater. The last one is connected to a helium recovery circuit and to a helium pumping system (4.5 g/s at 16 mbar). The Gersemi vertical cryostat is a part of FREIA cryogenic facility which also contains a helium liquefier and a horizontal cryostat inside of a bunker allowing the test of superconducting cavity cryomodules. The first results of the cryogenic tests on this equipment are reported.
Proceedings of the 19th International Conference on RF Superconductivity, SRF2019, Dresden, Germany
Databáze: OpenAIRE