Neonatal screening and selective sonographic imaging in the diagnosis of developmental dysplasia of the hip

Autor: R W Paton, Qas A. Choudry
Rok vydání: 2018
Předmět:
Zdroj: The bonejoint journal. (6)
ISSN: 2049-4408
2049-4394
Popis: Aims The aim of this prospective cohort study was to evaluate the effectiveness of the neonatal hip instability screening programme. Patients and Methods The study involved a four-year observational assessment of a neonatal hip screening programme. All newborns were examined using the Barlow or Ortolani manoeuvre within 72 hours of birth; those with positive findings were referred to a ‘one-stop’ screening clinic for clinical and sonographic assessment of the hip. The results were compared with previous published studies from this unit. Results A total of 124 newborns with a positive Barlow or Ortolani manoeuvre, clunk positive, or ‘unstable’ were referred. Five were found to have clinical instability of the hip. Sonographically, 92 newborns had Graf Type I hips, 12 had Graf Type II hips, and 20 had Graf Type IV hips. The positive predictive value (PPV) of clinical screening was 4.0% and the PPV of sonography was 16.1%. This has led to an increased rate of surgery for DDH. Conclusion Compared with previously published ten-year and 15-year studies, there has been a marked deterioration in the PPV in those referred with potential instability of the hip. There appears to be a paradox, with rising referrals and a decreasing PPV combined with an increasing rate of surgery in newborns with developmental dysplasia of the hip. Cite this article: Bone Joint J 2018;100-B:806–10.