Mammographic positioning quality of newly trained versus experienced radiographers in the Dutch breast cancer screening programme
Autor: | Gerard J. den Heeten, Mireille J. M. Broeders, Janine Timmers, Cary van Landsveld-Verhoeven |
---|---|
Přispěvatelé: | Cancer Center Amsterdam, Amsterdam Public Health, Biomedical Engineering and Physics, Radiology and Nuclear Medicine |
Rok vydání: | 2014 |
Předmět: |
medicine.medical_specialty
media_common.quotation_subject Breast Neoplasms Audit Patient Positioning Breast cancer screening Medicine Breast screening Inframammary fold Mammography Humans Mass Screening Radiology Nuclear Medicine and imaging Medical physics Quality (business) Mass screening Early Detection of Cancer media_common Netherlands medicine.diagnostic_test business.industry General Medicine Middle Aged Cross-Sectional Studies Female Radiology Clinical Competence business Quality assurance |
Zdroj: | European radiology, 25(11), 3322-3327. Springer Verlag |
ISSN: | 1432-1084 0938-7994 |
Popis: | Our purpose was to compare mammographic positioning quality of new (NR) versus experienced screening radiographers (ER) in the Netherlands. Before starting to work in breast screening, NR must complete an education programme including a theoretical course (four days), practical training (six weeks), and a portfolio-review of 50 mammographic screening examinations performed by the radiographer. Furthermore, Dutch screening has an extensive system of quality assurance, including an audit-review of positioning quality of mammograms by ER. We analysed 13,520 portfolio views (NR) and 14,896 audit views (ER) based on pre-specified criteria, e.g., depiction of inframammary angle. Overall positioning was more adequate for NR than ER (CC views: 97 % versus 86 %, p = 0.00; MLO views: 92 % versus 84 %, p = 0.00). NR scored better for most of the CC-criteria and showed, for instance, less folds (inadequate: 10 % versus 16 %, p = 0.00). In contrast, NR encountered more difficulties for MLO views in, for example, depiction of infra-mammary angle (inadequate: 38 % versus 34 %, p = 0.00). Overall, mammograms from NR were more often considered adequate, because of less severe errors. NR perform better than ER in overall positioning technique. These results stress the need for continuous monitoring and training in breast screening programmes to keep positioning skills up to date. • We evaluated positioning quality of new and experienced Dutch screening radiographers. • New radiographers outperform their experienced colleagues in mammographic positioning quality. • New radiographers make less severe errors compared to experienced colleagues. • There is a need for a continuous individual monitoring and feedback system. |
Databáze: | OpenAIRE |
Externí odkaz: |