Fault Detection and Management of the Three-Phase 4-Leg Voltage Source Inverter
Autor: | Luca Solero, Mi Tang, Pericle Zanchetta, M. di Benedetto, Alessandro Lidozzi |
---|---|
Přispěvatelé: | M. Tang, P. Zanchetta, M. d. Benedetto, A. Lidozzi and L. Solero, Tang, M., Zanchetta, P., di Benedetto, M., Lidozzi, A., Solero, L. |
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Observer (quantum physics)
Computer science resonant controller disturbance observer Fault detection and isolation fault detection Three-phase Control theory Electronic engineering Inverter Power semiconductor device MATLAB Field-programmable gate array three-phase four-leg inverter computer computer.programming_language |
Popis: | A novel fault detection and ride-through method for the three-phase 4-Leg Inverter (3$\Phi$4L Inverter) used in off-grid applications is addressed in this paper. Open circuit and short circuit faults of the power devices located in the $3 \Phi 4 \mathrm{~L}$ Inverter have been theoretically analyzed. Hence, the fault detection and converter protection strategy has been implemented using a combination of a resonant controller in the $\alpha \beta$ frame and a repetitive observer. The proposed strategy has been at first validated by means of simulation results performed in MATLAB/Simulink environment. The fault detection and ride-through algorithm has been then implemented in FPGA using LabVIEW environment and full experimental verification are performed on the prototype of the three-phase 4-leg inverter. |
Databáze: | OpenAIRE |
Externí odkaz: |