Caracterización del comportamiento óptico mediante curva de desenfoque: análisis de dos modelos de lentes intraoculares refractivas con adición alta y media
Autor: | Miguel Ángel Sánchez-Tena, Jorge A Calvo-Sanz |
---|---|
Rok vydání: | 2020 |
Předmět: |
Male
Visual acuity genetic structures medicine.medical_treatment Visual Acuity Medium addition Intraocular lens Instrumento óptico 0302 clinical medicine Lens Implantation Intraocular Lentes oftálmicas Prospective Studies Bifocal Intermediate distance Middle Aged Refraction High addition Intraocular lenses Oftalmología Female medicine.symptom Adición media Original article medicine.medical_specialty Biometry Materials science Pseudophakia Prosthesis Design Refraction Ocular Contrast Sensitivity Curva de desenfoque 03 medical and health sciences Ophthalmology Defocus curve medicine Humans Aged Phacoemulsification Curve analysis Cataract surgery Multifocal Intraocular Lenses Subjective refraction eye diseases 030221 ophthalmology & optometry Lentes intraoculares sense organs 030217 neurology & neurosurgery Adición alta Optometry |
Zdroj: | Journal of Optometry ABACUS. Repositorio de Producción Científica Universidad Europea (UEM) |
ISSN: | 1888-4296 |
DOI: | 10.1016/j.optom.2018.10.003 |
Popis: | Purpose To characterize the optical performance of two models of refractive bifocal intraocular lenses, with medium and high addition, using defocus curves. Methods 20 eyes from 20 subjects were included in this study. 10 eyes underwent caratact surgery with an implant of a medium addition refractive bifocal intraocular lens (IOL) (Lentis LS-313 MF20) and the other 10 eyes underwent cataract surgery with an implant of a high addition refractive bifocal IOL (Lentis LS-313 MF30). Six weeks after surgery, subjective refraction and defocus curve were made. Results Mean final residual refraction in spherical equivalent was +0.10 ± 0.07 D in the LS-313MF30 group and +0.12 ± 0.10 D in the LS-313MF20 group. Defocus curve showed a different optical performance in intermediate/near distance depending on the IOL model. The medium addition IOL provided good visual acuity (VA) at far and intermediate distance up to 50 cms, and the high addition IOL provided better VA in near distance up to 25 cms. Conclusions The high addition intraocular lens provides better visual acuity in the spatial range from infinity to the point close to 25 cm. The medium addition intraocular lens provides excellent visual acuity in far and intermediate vision. The defocus curve seems to be a valid and reproducible tool for evaluating the optical behavior of multifocal sector refractive lenses. Objetivo Caracterizar el comportamiento óptico de dos modelos de lentes intraoculares bifocales refractivas, con adición media y alta, utilizando curvas de desenfoque. Métodos Se incluyó en este estudio a 20 ojos de 20 sujetos: 10 ojos sometidos a cirugía de cataratas con implante de lentes intraoculares (LIO) bifocales refractivas con adición media (Lentis LS-313 MF20), y los 10 ojos restantes sometidos a cirugía de cataratas con implante de LIO bifocales refractivas de adición alta (Lentis LS-313 MF30). Transcurridas seis semanas de la cirugía, se realizó refracción subjetiva y curva de desenfoque. Resultados La refracción residual final media en el equivalente esférico fue de + 0,1 ± 0,07 D en el grupo LS-313MF30, y de + 0,12 ± 0,1 D en el grupo LS-313MF20. La curva de desenfoque mostró un comportamiento óptico diferente en la distancia intermedia/de cerca, dependiendo del modelo de LIO. La LIO de adición media aportó buena agudeza visual (AV) en la distancia de lejos e intermedia, de hasta 50 cm, y la LIO de adición alta aportó mejor AV en la distancia de cerca de hasta 25 cm. Conclusiones Las lentes intraoculares de adición alta aportan mejor agudeza visual en el rango espacial comprendido entre el infinito y el punto próximo a 25 centímetros. Las lentes intraoculares de adición media aportan una agudeza visual excelente en la visión de lejos e intermedia. La curva de desenfoque parece ser una herramienta válida y reproducible para evaluar el comportamiento óptico de las lentes refractivas multifocales. Sin financiación No data JCR 2020 0.844 SJR (2020) Q2, 4/10 Optometry No data IDR 2020 UEM |
Databáze: | OpenAIRE |
Externí odkaz: |