The Effect of Precooling on Exhaustive Performance in the Hot Environment
Autor: | Ali Gorzi, Aghaali Ghasemnian, Mansour Mousavi, Ahmad Azad |
---|---|
Rok vydání: | 2016 |
Předmět: |
business.industry
Applied psychology Advertising 030229 sport sciences Plasma volume Heat Temperature 03 medical and health sciences 0302 clinical medicine Exercise performance Medicine Orthopedics and Sports Medicine Plasma Volume business Exercise human activities 030217 neurology & neurosurgery Research Article |
Zdroj: | Asian Journal of Sports Medicine |
ISSN: | 2008-7209 2008-000X |
DOI: | 10.5812/asjsm.33125 |
Popis: | Background Pre-cooling is known to enhance exercise performance in soccer players. However, little information currently exists regarding precooling effects in Iranian young soccer players. Objectives The aim of this study was to assess the effect of precooling (water immersion) on exhaustive performance in the heat ( temperature = 32 - 34°C, humidity = 50%). Patients and Methods Sixteen young male soccer players from the provincial competitive teams were divided into two equal groups and were randomly assigned to precooling (age = 16.5 ± 1.1 year, height = 171.7 ± 6.4 cm, BMI = 21.5 ± 3.3, VO2max = 50.6 ± 6.9 mL/kg/min) and non-precooling (age = 16.1 ± 1.1 year, height = 170.0 ± 4.7 cm, BMI = 21.3 ± 3.6, VO2max = 50.6 ± 6.8 mL/kg/min) groups. An exhaustive treadmill run test was conducted after warm-up (non-precooling) or warm-up + water immersion (temperature = 22 - 24°C). Oral temperature, plasma lactate and plasma volume were measured at the baseline (fasting state), mid test (immediately after warm up or warm -up + water immersion) and post test (immediately after exhaustive test). Mixed repeated measures analysis of variance and independent t test were used for data analyzing. P < 0.05 was considered significant. Results There were no significant differences between two groups at baseline, mid test and post test regarding oral temperature and plasma lactate. The time to exhaustion was considerably higher in the precooling group compared with the non-precooling group, but the difference was not statistically significant. No significant differences were found between the two groups on measures of the baseline and mid test plasma volume, but post test plasma volume was significantly higher in the precooling group compared to the non-precooling group (P < 0.05). Conclusions These results show that precooling effectively attenuates dehydration, but has no positive effect on exhaustion time in the hot environment. |
Databáze: | OpenAIRE |
Externí odkaz: |