Point-of-care monitoring of perioperative intraocular pressure using portable tonometry in a patient with Posner-Schlossman syndrome: a case report
Autor: | Young-Jin Moon, Jong Yeon Park, Ashish Bangaari, Sung-Hoon Kim, Jihion Yu, Jin-Ho Rhim |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2014 |
Předmět: |
medicine.medical_specialty
Intraocular pressure genetic structures Monitoring Case Report Reconstruction surgery Tonometry lcsh:RD78.3-87.3 Blurred vision Anesthesiology medicine Anesthesia Point of care Posner-Schlossman syndrome business.industry Rotator cuff injury Perioperative medicine.disease eye diseases Surgery Anesthesiology and Pain Medicine lcsh:Anesthesiology sense organs medicine.symptom business |
Zdroj: | Korean Journal of Anesthesiology Korean Journal of Anesthesiology, Vol 66, Iss 3, Pp 248-251 (2014) |
ISSN: | 2005-7563 2005-6419 |
Popis: | A 56-year-old man with a rotator cuff injury, scheduled for arthroscopic reconstruction surgery, had a history of recurrent symptoms of eyeball pain and blurred vision for several years. After close examination, he was diagnosed with Posner-Schlossman syndrome. Three weeks before the scheduled surgery, his intraocular pressure (IOP) increased (> 30 mmHg) and he became extremely anxious about the surgery. We monitored his IOP intraoperatively and successfully completed general anesthesia without any sequelae. As Posner-Schlossman syndrome can present with severe complications that may lead to postoperative visual loss, intraoperative monitoring of intraocular monitoring and careful anesthetic management are crucial to protect vision. |