Popis: |
Volatile organic compounds (VOCs) are a significant class of indoor air pollutants and are known for their adverse effects on health. A common strategy to reduce indoor VOC levels is to use sorbents, including activated carbons (ACs). The amount of activated carbon is critical to achieving a reasonable AC filter lifetime in an air purification device. The study aims to estimate the amount of carbon needed in a typical indoor environment and in a heavy use setting such as during cooking, agriculture field fires, or wildfires. The problem is complex as various types of ACs are used, and the type and concentration of VOCs in the indoor environment also vary in different settings. Therefore, literature data on thermophysical parameters for 45 AC-VOC pairs was used to estimate the required amount of AC under a given set of conditions. The study uses modeling distributions of the footprint of suitable carbon filters for the removal of common VOCs encountered indoors for a period of 30 days. It was found that while 50% of AC-VOC pairs surveyed will require about 190-370 g at low indoor VOCs levels of 0.1-1 μmol/m |