Life-threatening and life-saving inappropriate implantable cardioverter defibrillator shocks

Autor: Ivo Roca-Luque, Jordi Pérez-Rodon, David Doiny, Angel Moya Mitjans, David Garcia-Dorado, Rosa María Lidón, Berta Miranda, Jaume Francisco-Pascual, Nuria Rivas-Gándara
Přispěvatelé: Institut Català de la Salut, [Pérez-Rodon J, Doiny D, Rivas-Gandara N, Roca-Luque I, Francisco-Pascual J, Moya Mitjans A] Unitat d’Arrítmies, Servei de Cardiologia, Vall d'Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain. [Miranda B, Lidón RM, García-Dorado D] Servei de Cardiologia, Vall d'Hebron Hospital Universitari, Barcelona, Spain. Universitat Autònoma de Barcelona, Bellaterra, Spain, Vall d'Hebron Barcelona Hospital Campus
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Equipment and Supplies::Electrical Equipment and Supplies::Electrodes::Defibrillators::Defibrillators
Implantable [ANALYTICAL
DIAGNOSTIC AND THERAPEUTIC TECHNIQUES
AND EQUIPMENT]

medicine.medical_specialty
implantable cardioverter defibrillator
medicine.medical_treatment
Case Report
Case Reports
macromolecular substances
030204 cardiovascular system & hematology
Otros calificadores::Otros calificadores::/efectos adversos [Otros calificadores]
equipos y suministros::equipos eléctricos y suministros eléctricos::electrodos::desfibriladores::desfibriladores implantables [TÉCNICAS Y EQUIPOS ANALÍTICOS
DIAGNÓSTICOS Y TERAPÉUTICOS]

03 medical and health sciences
0302 clinical medicine
Internal medicine
Implantable cardioverter defibrillator
medicine
Desfibril·ladors cardioversors implantables
Other subheadings::Other subheadings::/adverse effects [Other subheadings]
Lead Dislodgement
In patient
030212 general & internal medicine
Life saving
cardiovascular diseases
Ventricular fibrillation
Lead dislodgement
Inappropriate shock
ambiente y salud pública::salud pública::medidas epidemiológicas::demografía::estado de salud::calidad de vida [ATENCIÓN DE SALUD]
business.industry
Atrial fibrillation
General Medicine
medicine.disease
Implantable cardioverter-defibrillator
ventricular fibrillation
inappropriate shock
Environment and Public Health::Public Health::Epidemiologic Measurements::Demography::Health Status::Quality of Life [HEALTH CARE]
medicine.anatomical_structure
Qualitat de vida
Cardiology
cardiovascular system
Right atrium
lead dislodgement
business
Zdroj: Scientia
Recercat: Dipósit de la Recerca de Catalunya
Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Clinical Case Reports
Dipòsit Digital de Documents de la UAB
Universitat Autònoma de Barcelona
Recercat. Dipósit de la Recerca de Catalunya
instname
Popis: Atrial fibrillation; Implantable cardioverter defibrillator; Inappropriate shock Fibrilación auricular; Desfibrilador cardioversor implantable; Shock inapropiado Fibril·lació auricular; Desfibril·lador cardioversor implantable; Xoc inadequat An implantable cardioverter defibrillator (ICD) lead dislodgement into the right atrium is a dangerous situation, particularly in patients in atrial fibrillation because atrial fibrillation can be sensed as ventricular fibrillation and true ventricular fibrillation induced with an inappropriate shock. In the presence of shocks, ICD interrogation should be performed as soon as possible.
Databáze: OpenAIRE