The comparison study of the monopole tower foundation using CPT and laboratory data in Gresik district, East Java-Indonesia
Autor: | Sudjianto, Agus Tugas, Aditya, Chandra, Halim, Abdul, Fachrudin, Fachrudin |
---|---|
Rok vydání: | 2021 |
Předmět: |
Soil test
QC1-999 General Physics and Astronomy 02 engineering and technology monopole 0203 mechanical engineering Shallow foundation TJ1-1570 Carrying capacity Geotechnical engineering Mechanical engineering and machinery Bearing capacity Sondir data Terzaghi's principle Mathematics Physics 020502 materials General Engineering Foundation (engineering) laboratory data 020303 mechanical engineering & transports 0205 materials engineering tower foundation Foundation bearing capacity Tread Tower |
Zdroj: | EUREKA: Physics and Engineering, Iss 3, Pp 127-139 (2021) |
ISSN: | 2461-4262 2461-4254 |
DOI: | 10.21303/2461-4262.2021.001860 |
Popis: | In the millennial era, the development of information and communication technology is very fast, one of the telecommunications infrastructure is a monopole type telecommunications tower. This type of tower is one of 3 types of telecommunication towers whose main construction is made of steel. The monopole structure is supported by a tread foundation, which is one type of shallow foundation. The main factor in the design of the tread foundation is the bearing capacity factor. Calculation of foundation bearing capacity can be done directly in the field using Sondir data (CPT) and indirectly using laboratory data. In this study a study was conducted to compare the carrying capacity of monopole foundations between field data methods in the form of Sondir data or CPT with result data. Soil tests in the laboratory calculated with the Terzaghi formula. The research location was carried out in Gresik Regency, East Java Province, Indonesia at 3 sites, namely: Mojosarirejo, Kembangan Kebomas and Setromenganti. The results of the comparison of the calculation of the bearing capacity of the foundation (Q) at the Mojosarirejo site with the type of sandy soil. value of QSondir < 9.58 % of Qterzaghi. At the Krembangan Kebomas site with brown clay and gravely clay, the Q value was < 69.93 % of the Qterzaghi and at the Setromenganti site with brown clay soil type with the influence of water level depth – 1 m, the Q value was < 27, 62% of Qterzaghi. From the comparison of the average calculation in the 3 study locations, the bearing capacity of QSondir treads foundation is 26.50 % smaller than Qterzaghi, so the use of Sondir data is more accurate for use in tread foundation planning and provides greater security assurance for the tower foundation structure. monopole type |
Databáze: | OpenAIRE |
Externí odkaz: |