Dutch multicenter experience using the STENTYS Xposition S self-apposing stent in complex coronary lesions
Autor: | Alexander Ijsselmuiden, Sami Somi, Floris Kauer, Anais Balland, Cihan Simsek, Selina Vlieger, Gillian A.J. Jessurun, Giovanni Amoroso, Robert-Jan van Geuns |
---|---|
Přispěvatelé: | Cardiology |
Rok vydání: | 2019 |
Předmět: |
Male
medicine.medical_specialty Acute coronary syndrome Time Factors medicine.medical_treatment Coronary Artery Disease 030204 cardiovascular system & hematology Prosthesis Design Coronary artery disease 03 medical and health sciences 0302 clinical medicine Clinical endpoint medicine Humans Radiology Nuclear Medicine and imaging 030212 general & internal medicine Prospective Studies Registries Thrombus Acute Coronary Syndrome Angioplasty Balloon Coronary Aged Netherlands business.industry Coronary Thrombosis Percutaneous coronary intervention Stent Drug-Eluting Stents General Medicine Middle Aged medicine.disease Stenosis Treatment Outcome Female Radiology Cardiology and Cardiovascular Medicine business Mace |
Zdroj: | Catheterization and Cardiovascular Interventions, 94(7), 966-971. Wiley-Liss Inc. |
ISSN: | 1522-1946 |
Popis: | Objectives: The aim is to assess the experience in the Netherlands using the Xposition S self-apposing stent in complex coronary lesions in clinical practice. Background: Treatment of complex coronary lesions could be accompanied with stent sizing difficulties and complications, particularly due to vessel overdilation or stent underexpansion. The self-apposing feature of the Xposition S stent (STENTYS, Paris, France) supports good strut apposition in complex anatomies and allows for an increase in diameter after implantation. Methods: In this real-world registry, data from patients treated with Xposition S in four Dutch clinical sites were prospectively collected and analyzed. Any patient suitable for implantation with Xposition S according to current recommendations was enrolled. Primary endpoint was major adverse cardiac events (MACE) at 1 year. Results: Between 2015 and 2018, data from 251 patients were collected. Clinical presentation was an acute coronary syndrome in majority of the patients (76.9%). Main angiographic indications were lesions in aneurysmatic or ectatic vessels (32.3%), thrombus containing lesions (13.1%), and bifurcation/left main stenosis (10.4%). Most of the target lesions (TLs) were classified as AHA/ACC Type C (53.6%). Despite lesion complexity, device was successfully implanted at TL in 96.8%. MACE rate, reported on patients having completed 1-year follow-up (n = 203), was 6.6%, with low rate of definite/probable stent thrombosis (1.0%). Conclusions: In clinical practice of several Dutch sites, STENTYS Xposition S showed good procedural results and low 1-year clinical events rate, despite complex coronary anatomy. |
Databáze: | OpenAIRE |
Externí odkaz: |