Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study
Autor: | Juan A. Hernandez Tamames, Francesca Pennati, Anh H. Nguyen, Harm A.W.M. Tiddens, Pierluigi Ciet, Marleen de Bruijne, Piotr A. Wielopolski, Adria Perez-Rovira, Tetyana Ivanovska, Liesbeth Duijts, Andrea Aliverti |
---|---|
Přispěvatelé: | Pediatrics, Radiology & Nuclear Medicine, Medical Informatics, Erasmus MC other |
Rok vydání: | 2018 |
Předmět: |
Male
medicine.medical_specialty Population Phantoms Imaging phantom Imaging 030218 nuclear medicine & medical imaging Cohort Studies 03 medical and health sciences Imaging Three-Dimensional Magnetic resonance imaging 0302 clinical medicine Lung Lung volume measurements medicine Humans Radiology Nuclear Medicine and imaging Segmentation Lung volumes Magnetic Resonance Prospective Studies Child education Neuroradiology education.field_of_study medicine.diagnostic_test Phantoms Imaging business.industry Reproducibility of Results Isocenter General Medicine Gold standard (test) Magnetic Resonance Imaging Female Lung Volume Measurements ROC Curve 030220 oncology & carcinogenesis Three-Dimensional Radiology business |
Zdroj: | Nguyen, A H, Perez-Rovira, A, Wielopolski, P A, Hernandez Tamames, J A, Duijts, L, de Bruijne, M, Aliverti, A, Pennati, F, Ivanovska, T, Tiddens, H A W M & Ciet, P 2019, ' Technical challenges of quantitative chest MRI data analysis in a large cohort pediatric study ', European Radiology, vol. 29, no. 6, pp. 2770–2782 . https://doi.org/10.1007/s00330-018-5863-7 European Radiology European Radiology, 29(6), 2770-2782. Springer-Verlag |
ISSN: | 1432-1084 0938-7994 |
DOI: | 10.1007/s00330-018-5863-7 |
Popis: | Objectives This study was conducted in order to evaluate the effect of geometric distortion (GD) on MRI lung volume quantification and evaluate available manual, semi-automated, and fully automated methods for lung segmentation. Methods A phantom was scanned with MRI and CT. GD was quantified as the difference in phantom’s volume between MRI and CT, with CT as gold standard. Dice scores were used to measure overlap in shapes. Furthermore, 11 subjects from a prospective population-based cohort study each underwent four chest MRI acquisitions. The resulting 44 MRI scans with 2D and 3D Gradwarp were used to test five segmentation methods. Intraclass correlation coefficient, Bland–Altman plots, Wilcoxon, Mann–Whitney U, and paired t tests were used for statistics. Results Using phantoms, volume differences between CT and MRI varied according to MRI positions and 2D and 3D Gradwarp correction. With the phantom located at the isocenter, MRI overestimated the volume relative to CT by 5.56 ± 1.16 to 6.99 ± 0.22% with body and torso coils, respectively. Higher Dice scores and smaller intraobject differences were found for 3D Gradwarp MR images. In subjects, semi-automated and fully automated segmentation tools showed high agreement with manual segmentations (ICC = 0.971–0.993 for end-inspiratory scans; ICC = 0.992–0.995 for end-expiratory scans). Manual segmentation time per scan was approximately 3–4 h and 2–3 min for fully automated methods. Conclusions Volume overestimation of MRI due to GD can be quantified. Semi-automated and fully automated segmentation methods allow accurate, reproducible, and fast lung volume quantification. Chest MRI can be a valid radiation-free imaging modality for lung segmentation and volume quantification in large cohort studies. Key Points • Geometric distortion varies according to MRI setting and patient positioning. • Automated segmentation methods allow fast and accurate lung volume quantification. • MRI is a valid radiation-free alternative to CT for quantitative data analysis. Electronic supplementary material The online version of this article (10.1007/s00330-018-5863-7) contains supplementary material, which is available to authorized users. |
Databáze: | OpenAIRE |
Externí odkaz: |