Salvage of failed prior endovascular abdominal aortic aneurysm repair with fenestrated endovascular stent grafts
Autor: | Robert Fitridge, Donald J. Adam, David Ernest Hartley, Michael Berce, John Lennon Anderson |
---|---|
Rok vydání: | 2006 |
Předmět: |
Male
Reoperation medicine.medical_specialty medicine.medical_treatment Prosthesis Design Radiography Interventional Aortic aneurysm Angioplasty Medicine Humans cardiovascular diseases Mesenteric arteries Aged medicine.diagnostic_test business.industry Stent Angiography Digital Subtraction medicine.disease Abdominal aortic aneurysm Surgery Prosthesis Failure Ostium medicine.anatomical_structure surgical procedures operative Treatment Outcome Angiography cardiovascular system Stents Radiology business Cardiology and Cardiovascular Medicine Perfusion Aortic Aneurysm Abdominal |
Zdroj: | Journal of Vascular Surgery. 44(6):1341-1344 |
ISSN: | 0741-5214 |
DOI: | 10.1016/j.jvs.2006.07.047 |
Popis: | Three patients with type I proximal endoleak after previous endovascular abdominal aortic aneurysm (AAA) repair were treated with fenestrated endovascular stent grafts. Six renal arteries, three superior mesenteric arteries, and one coeliac axis were targeted for incorporation by graft fenestration. The fenestration-renal ostium interface was secured with balloon-expandable stents and completion angiography demonstrated no endoleaks and antegrade perfusion in all target vessels. All patients made an uncomplicated recovery. Fenestrated endovascular stent grafts can be used to salvage failed prior endovascular AAA repair in patients who are considered unsuitable for other endovascular or open surgical interventions. |
Databáze: | OpenAIRE |