Comparison of scandium-44 g with other PET radionuclides in pre-clinical PET phantom imaging
Autor: | Frank Wuest, Hans-Sonke Jans, Simon Ferguson, Melinda Wuest, T. Riauka |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2019 |
Předmět: |
lcsh:Medical physics. Medical radiology. Nuclear medicine
Materials science Image quality lcsh:R895-920 media_common.quotation_subject Radiometals Biomedical Engineering PET imaging Field of view Iterative reconstruction Imaging phantom 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine Ordered subset expectation maximization Contrast (vision) Radiology Nuclear Medicine and imaging Instrumentation media_common Original Research Radiation Radon transform 030220 oncology & carcinogenesis Scandium Preclinical imaging Biomedical engineering |
Zdroj: | EJNMMI Physics EJNMMI Physics, Vol 6, Iss 1, Pp 1-14 (2019) |
ISSN: | 2197-7364 |
Popis: | Purpose The decay characteristics of radionuclides in PET studies can impact image reconstruction. 44gSc has been the topic of recent research due to potential theranostic applications and is a promising radiometal for PET imaging. In this study, the reconstructed images from phantom measurements with scandium in a small-animal PET scanner are compared with 18F and two prominent radiometals: 64Cu and 68Ga Methods Three phantoms filled with 18F, 64C, 68Ga, and 44gSc were imaged in the Siemens Inveon PET scanner. The NEMA image quality phantom was used to determine the recovery coefficients (RCs), spill-over ratios (SORs), and noise (%SD) under typical pre-clinical imaging conditions. Image contrast was determined using a Derenzo phantom, while the coincidence characteristics were investigated using an NEC phantom. Three reconstruction algorithms were used, namely filtered back projection (FBP), ordered subset expectation maximization (OSEM), and maximum a-posteriori (MAP). Results Image quality parameters were measured for 18F, 64Cu, 68Ga, and 44gSc respectively; using FBP, the %SD are 5.65, 5.88, 7.28, and 7.70; the RCs for the 5-mm rod are 0.849, 1.01, 0.615, and 0.825; the SORs in water are 0.0473, 0.0595, 0.141, 0.0923; and the SORs in air are 0.0589, 0.0484, 0.0525, and 0.0509. The contrast measured in the 2.5-mm rods are 0.674, 0.637, 0.196, and 0.347. The NEC rate with 44gSc increased at a slower rate than 18F and 68Ga as a function of activity in the field of view. Conclusion 44gSc demonstrates intermediate behavior relative to 18F and 68Ga with regard to RC and contrast measurements. It is a promising radionuclide for preclinical imaging. |
Databáze: | OpenAIRE |
Externí odkaz: |