Detection of Pulmonary Embolism with Gallium-68 Macroaggregated Albumin Perfusion PET/CT: An Experimental Study in Rabbits

Autor: Ayşe Uğur, Ferda Bir, Mustafa Cagdas Cayir, Aziz Gültekin, Doğangün Yüksel
Jazyk: angličtina
Rok vydání: 2020
Předmět:
gallium 68
Perfusion scanning
030218 nuclear medicine & medical imaging
0302 clinical medicine
medical examination
Positron Emission Tomography Computed Tomography
nuclear medicine
macroaggregated albumin ga 68
single photon emission computed tomography-computed tomography
Pulmonary embolism
unclassified drug
Perfusion
medicine.anatomical_structure
priority journal
030220 oncology & carcinogenesis
histopathology
Macroaggregated albumin
diagnostic accuracy
sham procedure
Rabbits
lung embolism
Research Article
Article Subject
animal experiment
Leporidae
Article
experimental study
animal tissue
03 medical and health sciences
Animal model
Organometallic Compounds
medicine
Medical technology
Animals
Radiology
Nuclear Medicine and imaging

controlled study
diagnostic test accuracy study
R855-855.5
Serum Albumin
albumin
Tomography
Emission-Computed
Single-Photon

PET-CT
Lung
nonhuman
business.industry
animal model
reference value
medicine.disease
lung ventilation
sensitivity and specificity
Rabbit model
Pulmonary Embolism
Nuclear medicine
business
Zdroj: Contrast Media & Molecular Imaging, Vol 2020 (2020)
Contrast Media & Molecular Imaging
ISSN: 1555-4317
1555-4309
Popis: Purpose To evaluate the use of gallium-68 ( 68 Ga) macroaggregated albumin (MAA) positron emission tomography/computed tomography (PET/CT) perfusion imaging combined with Technegas single-photon emission computed tomography/computed tomography (SPECT/CT) ventilation imaging in rabbits with experimental pulmonary emboli (PE). Methods Technegas SPECT/CT ventilation and a 68 Ga-MAA PET/CT perfusion scan (V/Q scan) were performed in 12 rabbits before and one hour after artificial induction of PE. Technegas SPECT/CT and 68 Ga-MAA PET/CT images were evaluated by a nuclear medicine physician who recorded the presence, number, and location of PE on a per-lobe basis. The sensitivity, specificity, and accuracy of Technegas SPECT/CT and 68 Ga-MAA PET/CT for detecting PE were calculated using a histopathological evaluation as a reference standard. Results A total of 60 lung lobes were evaluated in 12 rabbits, and PE was detected in 20 lobes in V/Q scans and histopathological analysis. The overall sensitivity, specificity and accuracy were 100%, 100%, and 100%, respectively, for both the Technegas SPECT/CT and 68 Ga-MAA PET/CT V/Q scans. Conclusion Technegas/ 68 Ga-MAA V/Q scans have good sensitivity, specificity and accuracy in the detection of PE in this animal model study.
Databáze: OpenAIRE