Transpupillary thermotherapy threshold parameters: funduscopic, angiographic, and histologic findings in pigmented and nonpigmented rabbits
Autor: | Yanno Bezerra, Darius M. Moshfeghi, Fatemah Ghahramani, Mahmoud Genaidy, Po-Cheng Kuo, Gholam A. Peyman, Yoko Nishiyama-Ito, Gamze Men, Shin Yoneya |
---|---|
Rok vydání: | 2003 |
Předmět: |
Hyperthermia
medicine.medical_specialty Time Factors Fluence Radiation Tolerance Retina Body Temperature Lesion Ophthalmoscopy Eye Injuries Retinal Diseases Ophthalmology medicine Animals Fluorescein Angiography Pigment Epithelium of Eye Laser Coagulation medicine.diagnostic_test business.industry Pupil General Medicine Hyperthermia Induced medicine.disease Fluorescein angiography Contact lens Sensory Thresholds Models Animal Optic nerve Laser exposure Rabbits medicine.symptom business |
Zdroj: | Retina (Philadelphia, Pa.). 23(3) |
ISSN: | 0275-004X |
Popis: | Purpose To evaluate the effect of pigmentation on threshold fluence levels, needed to produce visible and angiographic lesions, of transpupillary thermotherapy (TTT) in rabbits. Methods Six pigmented and nine nonpigmented rabbits underwent TTT with an 810-nm diode laser coupled to a slit-lamp biomicroscope using a spot size of 2 or 3 mm. The power ranged from 80 to 200 mW with 1 to 3 minutes of laser exposure for pigmented rabbits and 750 to 1800 mW with 1 minute of exposure for albino rabbits. These parameters were also evaluated after compression of the globe using the contact lens to induce blanching of the optic nerve head. After the experiment, the eyes were enucleated under deep anesthesia, and the animals were killed immediately. Results In pigmented rabbits, the threshold fluence with the 2-mm spot size was 229 J/cm2 without compression and 153 J/cm2 with compression. With the 3-mm spot size, the threshold decreased from 200 to 150 mW as the duration of exposure lengthened (2 or 3 minutes), increasing the fluence from 170 to 382 J/cm2. In nonpigmented rabbits, the threshold fluence with the 2-mm spot size was 2,865 J/cm2 without compression and 2,674 J/cm2 with compression. With the 3-mm spot size, the threshold fluence of 1,528 J/cm2 was not affected by compression. Histopathologic studies showed transretinal damage at the lowest levels necessary to achieve angiographic evidence of a treatment lesion or a barely visible funduscopic lesion at the time of treatment. Conclusions Nonpigmented rabbits required more than a 12-fold increase in total TTT fluence compared with pigmented rabbits with the 2-mm spot size and a ninefold increase with the 3-mm spot size. Inner and outer retinal damage was seen histopathologically at these levels. |
Databáze: | OpenAIRE |
Externí odkaz: |