Assessment of narrow angles by gonioscopy, Van Herick method and anterior segment optical coherence tomography
Autor: | Michael S. Kook, Seong Bae Park, Kyoung Sub Lee, Sung Yung Kang, Jung Woo Jo, Kyung Rim Sung |
---|---|
Rok vydání: | 2011 |
Předmět: |
Male
medicine.medical_specialty genetic structures Gonioscopy Glaucoma Diagnostic Techniques Ophthalmological Sensitivity and Specificity Optics Optical coherence tomography Anterior Eye Segment Predictive Value of Tests Ophthalmology Area under curve medicine Humans Aged medicine.diagnostic_test business.industry Reproducibility of Results General Medicine Middle Aged medicine.disease eye diseases ROC Curve Area Under Curve Female sense organs Tomography Glaucoma Angle-Closure business Glaucoma Open-Angle Tomography Optical Coherence Geology |
Zdroj: | Japanese Journal of Ophthalmology. 55:343-350 |
ISSN: | 1613-2246 0021-5155 |
DOI: | 10.1007/s10384-011-0036-0 |
Popis: | To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT).One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients.The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63).Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD. |
Databáze: | OpenAIRE |
Externí odkaz: |