Intraocular pressure measurement in sheep using an applanation tonometer
Autor: | Fabiana Quartiero Pereira, Alberto André Ribeiro Silva, João Antonio Tadeu Pigatto, Luciana Vicente Rosa Pacicco de Freitas, Paula Stieven Hünning, Luis Felipe Dutra Corrêa, Luciane de Albuquerque, Bernardo Stefano Bercht |
---|---|
Rok vydání: | 2011 |
Předmět: |
Ovis aries
pressão intraocular Applanation tonometry sheep Intraocular pressure medicine.medical_specialty genetic structures Ophthalmic examination lcsh:Biotechnology Glaucoma lcsh:TP248.13-248.65 Ophthalmology medicine lcsh:Agriculture (General) Fluorescence staining tonometry General Veterinary business.industry Applanation tonometer medicine.disease lcsh:S1-972 eye diseases glaucoma tonometria sense organs Slit lamp biomicroscopy Ophthalmic disease General Agricultural and Biological Sciences business intraocular pressure ovelha |
Zdroj: | Revista Ceres, Vol 58, Iss 6, Pp 685-689 (2011) Revista Ceres v.58 n.6 2011 Revista Ceres Universidade Federal de Viçosa (UFV) instacron:UFV |
ISSN: | 0034-737X |
DOI: | 10.1590/s0034-737x2011000600002 |
Popis: | The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area. |
Databáze: | OpenAIRE |
Externí odkaz: |