A prospective 24 months follow-up of a three component press-fit prosthesis for hallux rigidus

Autor: L. Trtik, Jaap Harlaar, B.J. Burger, N.P. Saragas, S. Wassink, J. Asunción Márquez
Rok vydání: 2016
Předmět:
Zdroj: Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 23(3)
ISSN: 1460-9584
Popis: The aim of this study was to evaluate the results following total first metatarsophalangeal (FMTP) joint replacement arthroplasty using a modular three component press fit prosthesis at two year follow up.All patient data was collected in a prospective way in four study centres. Both preoperative and postoperative evaluation consisted of an assessment using the AOFAS-HMI score, visual analogue scale for pain, evaluation of the range of motion and patient satisfaction scores. Postoperative X-rays were reviewed for loosening and radiolucency up to two years.Fifty-five feet were available for analysis at 24 months. Two implants were removed during the study. Six more feet had additional surgery due to stiffness or malalignment. Postoperative AOFAS-HMI scores improved significantly by 32.4 points at two year follow-up (p0.001). The visual analogue scale for pain improved significantly from 6.8 (std 1,6) preoperatively to 1.6 (std 1,9) postoperatively (p0.0001). Mean dorsiflexion improved from 12.6 (std 10,1) degrees preoperatively to 31.2 (std 16,8) degrees postoperatively. Eighty-seven percent of patients were moderately to well satisfied with the end result. Eighteen prostheses showed radiolucency at 24 months.Implantation of a Metis