Evaluation of a graded exercise test to determine peak fat oxidation in individuals with low cardiorespiratory fitness
Autor: | Keith Stokes, James A. Betts, Robert M. Edinburgh, Oliver J. Chrzanowski-Smith, Javier T. Gonzalez |
---|---|
Rok vydání: | 2018 |
Předmět: |
Adult
Male medicine.medical_specialty Physiology Endocrinology Diabetes and Metabolism 030209 endocrinology & metabolism Incremental exercise Random Allocation Young Adult 03 medical and health sciences 0302 clinical medicine Fat oxidation Physiology (medical) Internal medicine medicine Humans Exercise metabolism Graded exercise test Cross-Over Studies Nutrition and Dietetics business.industry Cardiorespiratory fitness 030229 sport sciences General Medicine Lipid Metabolism Kinetics Cardiorespiratory Fitness Exercise Test Cardiology Female Energy Metabolism business Oxidation-Reduction |
Zdroj: | Applied Physiology, Nutrition, and Metabolism. 43:1288-1297 |
ISSN: | 1715-5320 1715-5312 |
DOI: | 10.1139/apnm-2018-0098 |
Popis: | The maximal capacity to utilise fat (peak fat oxidation, PFO) may have implications for health and ultra-endurance performance and is commonly determined by incremental exercise tests employing 3-min stages. However, 3-min stages may be insufficient to attain steady-state gas kinetics, compromising test validity. We assessed whether 4-min stages produce steady-state gas exchange and reliable PFO estimates in adults with peak oxygen consumption < 40 mL·kg−1·min−1. Fifteen participants (9 females) completed a graded test to determine PFO and the intensity at which this occurred (FATMAX). Three short continuous exercise sessions (SCE) were then completed in a randomised order, involving completion of the graded test to the stage (i) preceding, (ii) equal to (SCEequal), or (iii) after the stage at which PFO was previously attained, whereupon participants then continued to cycle for 10 min at that respective intensity. Expired gases were sampled at minutes 3–4, 5–6, 7–8, and 9–10. Individual data showed steady-state gas exchange was achieved within 4 min during SCEequal. Mean fat oxidation rates were not different across time within SCEequal nor compared with the graded test at FATMAX (both p > 0.05). However, the graded test displayed poor surrogate validity (SCEequal, minutes 3–4 vs. 5–6, 7–8, and 9–10) and day-to-day reliability (minutes 3–4, SCEequal vs. graded test) to determine PFO, as evident by correlations (range: 0.47–0.83) and typical errors and 95% limits of agreement (ranges: 0.03–0.05 and ±0.09–0.15 g·min−1, respectively). In conclusion, intraindividual variation in PFO is substantial despite 4-min stages establishing steady-state gas exchange in individuals with low fitness. Individual assessment of PFO may require multiple assessments. |
Databáze: | OpenAIRE |
Externí odkaz: |