The coupling of anisotropy and radial dose functions for 103Pd and 125I for use with a commercial treatment planning system
Autor: | Donald F. Dubois, James J. Prete, William S. Bice, Bradley R. Prestidge |
---|---|
Rok vydání: | 1997 |
Předmět: |
Radioisotopes
medicine.medical_specialty Point source Computer science Radiotherapy Planning Computer-Assisted medicine.medical_treatment Brachytherapy Interstitial brachytherapy Isotropy Reproducibility of Results Radiotherapy Dosage General Medicine Models Theoretical Iodine Radioisotopes Radiation therapy medicine Applied mathematics Dosimetry Medical physics Anisotropy Radiation treatment planning Algorithms Palladium |
Zdroj: | Medical Physics. 24:523-525 |
ISSN: | 0094-2405 |
Popis: | Many commercial treatment planning systems available today employ traditional dose calculation formulae in their interstitial brachytherapy source calculation algorithms. The 1995 AAPM report on interstitial brachytherapy source dosimetry recommended a new dose calculational formalism and presented a technique for adopting it on systems which embody traditional formalism. In order to comply with these recommendations on our system, the transformations for implementing a one dimensional isotropic point source model were modified by coupling the published anisotropy and radial dose corrections and fitting them to a fifth order polynomial. Using this approach, a more accurate dose calculation is obtained. |
Databáze: | OpenAIRE |
Externí odkaz: |